Dimensions H1P 069/078
Connector :
Deutsch DT04-2P
to be paint free
Shafts
to be paint free
12.45 ±0.25
[0.49 ±0.01]
45.2 ±1.0
[1.78 ±0.04]
139.3 ±1.0
[5.48 ±0.04]
154.2 ±1.0
[6.07 ±0.04]
52.0 ±0.2
[2.05 ±0.01]
89.0 ±0.2
[3.50 ±0.01]
92.4 ±0.2
[3.64 ±0.01]
(4x)
57.2 ±0.25
[2.25 ±0.01]
(8x)
28.6 ±0.25
[1.13 ±0.01]
135.7 ±1.0
[5.34 ±0.04]
48.0 ±1
[1.89 ±0.04]
69.5 ±1.0 [2.74 ±0.04]
104.0 ±1.0 [4.09 ±0.04]
126.1 ±1.0 [4.96 ±0.04]
152.9 ±1.0 [6.02 ±0.04]
278.3 ±2
[10.958 ±0.079]
(8x)13.9 ±0.25 [0.55 ±0.01]
(4x)27.8 ±0.25 [1.09 ±0.01]
R 0.8 max.
[0.031]
1.5 ±0.5 x 45°±5°
[0.059 ±0.020 x 45°]
214.0 + 0.6
– 0.5
[8.426 + 0.024
– 0.020
]
216.0 + 0.6
– 0.5
[8.505 + 0.024
– 0.020
]
∅
127.0
0
– 0.05
[5.0
0
– 0.002
]
65.0
+ 0.1
– 0.2
[2.559
+ 0.004
– 0.008
]
65.0
+ 0.1
– 0.2
[2.559
+ 0.004
– 0.008
]
P003 326E
B-B
(2x)
D-D
C-C
B
B
C
C
D
D
Shaft L
c
Shaft L
c
Shaft L
c
Z
31.5 ±1
[1.24 ±0.04]
8.05 ±0.8
[0.32 ±0.03]
15 ±0.2
[0.59 ±0.01]
Case drain port “L4”
Port ISO 11926-1 - 1
1
/
16
-12
∅
48.0 max. clearance
dia for fitting
Case pressure port
Port ISO 11926-1 -
7
/
8
-14
∅
42.0 max. clearance dia for fitting
Servo gauge port “M4”
Port ISO 11926-1 -
7
/
16
-20
∅
21 max. clearance
dia for fitting
Charge inlet port “S”
Port ISO 11926-1 - 1
5
/
16
-12
∅
63.0 max. clearance
dia for fitting
System port “B”
∅
25.4 – 450 bar
Split flange boss
per ISO 6162
M12x1.75
20 min. full thread depth
recommended screw-in
depth 1.5 x thread dia
System port “A”
∅
25.4 – 450 bar
Split flange boss
per ISO 6162
M12x1.75
20 min. full thread depth
recommended screw-in
depth 1.5 x thread dia
Mounting flange surface
Flange 127 - 4 per ISO 3019-1
to be paint free
Coupling must not
protrude beyond
this surface
Please contact Danfoss representative for specific installation drawings.
Technical Information
H1 Axial Piston Single Pumps, Size 069/078
Installation drawings
52 |
©
Danfoss | May 2017
11062169 | BC00000058en-US0801