10 | © Danfoss FT1555-BM230 Bench Mount Hose Capping System Operator’s Manual | 2023.04.
AQ453954047097en-010101
All electrical components comply with the relevant safety regulations. Repairs to the electrical components should only be performed by a qualified
electrician. Otherwise, the user may run the risk of accidents.
Advised Spare parts
Troubleshooting
Repairs
Part Number Item
Description
Exploded view #
230V-AK
2.0 AK
UC-HG5000E
HG5000E 230V Heat Gun
6
UC-1955K22
CSS- Plastic Fan Guard with Filter Insert
12
UC-2572K25
CapSeal System Bumper Feet
13
FT1555-SMP
Small Puck
FT1555-LMP
Large Puck
Problem
Cause
Solution
Capsule does not fit properly
Wrong diameter capsule for application
Measure outside diameter of the fitting and use
advised capsule.
Capsule doesn’t shrink
Machine is turned off/ Not heated to max
temp.
Turn on machine as described in section 2.4
Reference Time chart on page 7
Capsules melt during shrinking
process
Temperature is too high.
Holding capsule in the AK for more than
5 seconds
Check foam filter and air inlet of the Heat gun.
Clean both filters as described under 3.1.
Check temperature settings. Display on heat
gun should read as follows:
FT1555-BM230 325-330ºC
Unit doesn’t blow air
Faulty electrical
Overheating
Check breaker and power supply.
Check filters and clean as described under 3.1