11
Produced by Danfoss Floor Heating Hydronics 05.2011
VI.CU.C2.02
Instruction FH-CWP Thermostat
8. Maximum floor temperature
protection (Optional)
The function allows you to set a maximum allowable
floor temperature if for instance you want to protect
real wood floors from damage due to excess heat. For
specific maximum floor temperatures please refer to
recommendations from floor suppliers.
Displaying the Floor Temperature
The function allows you to check the internal tem-
perature of the floor. Works only with floor sensor.
Turn ON the thermostat by pressing Fig. 1
.
• Press
M
Fig. 1
shortly and
will flash in the
display.
• The actual floor temperature is shown in the
display.
Setting maximum floor temperature
Turn OFF the thermostat by pressing Fig. 1
• Press
M
Fig. 1
for 5 seconds until the display
shows
.
• Release
M
Fig.1
, and the display shows
.
• Press or Fig. 1
to set the desired maximum
floor temperature limit.
• Wait 5 seconds for the thermostat to exit SET mode
and power off.