Parameter Name - ERC 213

Code

Min

Max

Unit

App. 0

(Def.)

App. 1 App. 2 App. 3 App. 4 App. 5 App. 6

Max defrost time

d04

0

480

min

30

45

15

15

30

30

30

Defrost delay at power up 

(or DI signal)

d05

0

240.0

min

0

0

0

0

0

0

-

Drip delay

d06

0

60

min

0

0

0

0

0

0

5

Fan delay after defrost

d07

0

60

min

0

0

0

0

0

0

5

Fan start temperature 

after defrost

d08

-50.0

0.0

C/F

-5.0

-

-

-

-5.0

-5.0

-

Fan during defrost

d09

oFF

on

on

on

on

on

on

on

on

Defrost stop sensor

configuration 

non=time, 
Air=Sair (air temperature),
dEF=S5 (defrost sensor)

d10

non

dEF

non

non

non

non

dEF

dEF

non

Compressor accumulated

runtime to start defrost, 

0=OFF

d18

0

96

hours

0

0

0

0

0

0

-

Defrost on demand 

20.0=OFF

d19

0.0

20.0

K

20.0

-

-

-

20.0

20.0

-

Defrost delay after pull-down 

0=OFF

d30

0

960

min

0

0

0

0

0

0

-

Fan control

F--

Fan at compressor cutout

FFc=fan follow compressor, 
FAo=fan always ON, 
FPL= fan pulsating

F01

FFc

FPL

FAo

FAo

FAo

FAo

FAo

FAo

FAo

Fan stop evaporator temperature 

50.0=OFF

F04

-50.0

50.0

C/F

50.0

-

-

-

50.0

50.0

-

Fan ON cycle

F07

0

15

min

2

2

2

2

2

2

2

Fan OFF cycle

F08

0

15.0

min

2

2

2

2

2

2

2

Compressor

c--

Compressor minimum ON time

C01

0

30

min

0

0

0

0

0

0

0

Compressor minimum OFF time

C02

0

30

min

2

2

2

2

2

2

2

Compressor OFF delay 

at door open

C04

0

15

min

0

0

0

0

0

0

1

Zero crossing selection

C70

no

yES

yES

yES

yES

yES

yES

yES

yES

Others

o--

Delay of outputs 

at startup

o01

0

600

min

5

5

5

5

5

5

5

DI1 configuration 

oFF=not used, Sdc=status display 
output, doo=door alarm with 
resumption, doA=door alarm without 
resumption, SCH=main switch, 
nig=day / night mode, rFd=reference 
displacement, EAL=external alarm, 
dEF=defrost, Pud=pull-down, 
Sc=condenser sensor

o02

oFF

Sc

oFF

oFF

oFF

oFF

oFF

oFF

oFF

Serial address

o03

0

247

0

0

0

0

0

0

-

Password

o05

no

999

no

no

no

no

no

no

no

Sensor type selection

n5=NTC 5 K, n10=NTC 10 K, 
Ptc=PTC, Pt1=Pt1000

o06

n5

Pt1

n10

n10

n10

n10

n10

n10

-

Display resolution 

0.1=steps of 0.1 °C, 
0.5=steps of 0.5 °C, 
1.0=steps of 1.0 °C 

o15

0.1

1.0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

Relay 1 counter 

(1 count=100 cycles of operation)

o23

0

999

0

0

0

0

0

0

-

N.B.: hidden parameters are greyed out

Содержание ERC 213

Страница 1: ...X 5V Danfoss 80G8136 02 Programming key EKA 183B Electrical input on the basis of product code Installation guide ERC 213 Digital regulator for refrigeration and defrosting 3 relays Rear mount clip fixing Drilling template Dimensions mm Assembly Wiring diagram The ERC 213 is a smart multipurpose refrigeration controller with temperature and defrost management available with 3 relays The controller...

Страница 2: ...irm The regulator presets the parameter values on the basis of the application selected and hides any irrelevant parameters Tip you can easily switch from AP0 to AP6 and therefore select the simplified parameters list by pressing the UP button circular list STEP 4 Select the sensor type o06 The display automatically shows the sensor selection parameter o06 Press SET to select the type of sensor Th...

Страница 3: ...l the parameter groups To scroll the parameter names 5 Quick configuration with cFg menu Press SET for three seconds to open the parameter groups Select the cFg menu and press SET to open The first menu r12 main switch is displayed Set the main switch to OFF r12 0 to change the preinstalled application Press UP DOWN to scroll through the parameters list Configure the parameter o61 to select a prei...

Страница 4: ...ved The alarm bell is shown After 5 minutes of inactivity the keypad will be locked if P76 YES When the keypad is locked if any key is selected LoC appears on the display Press UP and DOWN buttons simultaneously for 3 seconds to unlock the keyboard unl is displayed for 3 seconds SET saves the temperature setpoint 7 Default application settings App Mode Description Temp Def type Def end App 0 Cooli...

Страница 5: ...105 C 40 221 F Controller accuracy 1 K below 35 C 0 5 K between 35 25 C 1 K above 25 C Output Compressor relay DO1 16 A 16 16 A EN 60730 10 FLA 60 LRA at 230 V UL60730 16 FLA 72 LRA at 115 V UL60730 Defrosting relay DO2 8 A 2 FLA 12 LRA UL60730 8 A 2 2 A EN60730 Fan relay DO3 3 A 2 FLA 12 LRA UL60730 3 A 2 2 A EN60730 Display LED 3 figure display decimal point and multifunction icons C F scale Ope...

Страница 6: ... 0 0 0 0 0 0 0 0 0 Thermostat reference displacement offset temperature r40 50 0 50 0 K 0 0 0 0 0 0 0 0 0 0 0 0 Pull down duration r96 0 960 min 0 0 0 0 0 0 Pull down limit temperature r97 100 0 200 0 C F 0 0 0 0 0 0 0 0 0 0 0 0 Alarm A Delay for temperature alarm during normal conditions A03 0 240 min 30 45 30 30 30 30 30 Delay for temperature alarm during pull down start up defrost A12 0 240 min...

Страница 7: ...FAo FAo FAo FAo FAo FAo FAo Fan stop evaporator temperature 50 0 OFF F04 50 0 50 0 C F 50 0 50 0 50 0 Fan ON cycle F07 0 15 min 2 2 2 2 2 2 2 Fan OFF cycle F08 0 15 0 min 2 2 2 2 2 2 2 Compressor c Compressor minimum ON time C01 0 30 min 0 0 0 0 0 0 0 Compressor minimum OFF time C02 0 30 min 2 2 2 2 2 2 2 Compressor OFF delay at door open C04 0 15 min 0 0 0 0 0 0 1 Zero crossing selection C70 no y...

Страница 8: ...arm dEF defrost Pud pull down o37 oFF Pud oFF oFF oFF oFF oFF oFF oFF Predefined applications o61 AP0 AP6 AP0 AP1 AP2 AP3 AP4 AP5 Save settings as factory WARNING the earlier factory settings are overwritten o67 no yES no no no no no no DO2 config dEF defrost ALA alarm o71 dEF ALA dEF ALA dEF dEF dEF dEF dEF Display at defrost Air actual air temperature FrE freezed temperature d d is displayed o91...

Страница 9: ...Name ERC 213 Code Min Max Unit App 0 Def App 1 App 2 App 3 App 4 App 5 App 6 Readouts u Controller Status S0 cooling ON Heating ON S2 wait for compressor ON time to elapse S3 wait for compressor OFF time to elapse restart time S4 drip OFF delay after defrost S10 cooling stop S11 cooling stopped by thermostat heating OFF S14 defrosting state S15 fandelaystateafterdefrost S17 door open DI input S20 ...

Отзывы: