15-74

Option

 in

 Slot

 C0

15-75

Slot

 C0

 Option

 SW

 Version

15-76

Option

 in

 Slot

 C1

15-77

Slot

 C1

 Option

 SW

 Version

15-9*

Parameter

 Info

15-92

Defined

 Parameters

15-93

Modified

 Parameters

15-98

Drive

 Identification

15-99

Parameter

 Metadata

16-**

Data

 Readouts

16-0*

General

 Status

16-00

Control

 Word

16-01

Reference

 [Unit]

16-02

Reference

 [%]

16-03

Status

 Word

16-05

Main

 Actual

 Value

 [%]

16-09

Custom

 Readout

16-1*

Motor

 Status

16-10

Power

 [kW]

16-11

Power

 [hp]

16-12

Motor

 Voltage

16-13

Frequency

16-14

Motor

 Current

16-15

Frequency

 [%]

16-16

Torque

 [Nm]

16-17

Speed

 [RPM]

16-18

Motor

 Thermal

16-22

Torque

 [%]

16-26

Power

 Filtered

 [kW]

16-27

Power

 Filtered

 [hp]

16-3*

Drive

 Status

16-30

DC

 Link

 Voltage

16-32

Brake

 Energy

 /s

16-33

Brake

 Energy

 /2

 min

16-34

Heatsink

 Temp.

16-35

Inverter

 Thermal

16-36

Inv.

 Nom.

 Current

16-37

Inv.

 Max.

 Current

16-38

SL

 Controller

 State

16-39

Control

 Card

 Temp.

16-40

Logging

 Buffer

 Full

16-41

Logging

 Buffer

 Full

16-43

Timed

 Actions

 Status

16-49

Current

 Fault

 Source

16-5*

Ref.

 &

 Feedb.

16-50

External

 Reference

16-52

Feedback

 [Unit]

16-53

Digi

 Pot

 Reference

16-54

Feedback

 1

 [Unit]

16-55

Feedback

 2

 [Unit]

16-56

Feedback

 3

 [Unit]

16-58

PID

 Output

 [%]

16-6*

Inputs

 &

 Outputs

16-60

Digital

 Input

16-61

Terminal

 53

 Switch

 Setting

16-62

Analog

 Input

 53

16-63

Terminal

 54

 Switch

 Setting

16-64

Analog

 Input

 54

16-65

Analog

 Output

 42

 [mA]

16-66

Digital

 Output

 [bin]

16-67

Pulse

 Input

 #29

 [Hz]

16-68

Pulse

 Input

 #33

 [Hz]

16-69

Pulse

 Output

 #27

 [Hz]

16-70

Pulse

 Output

 #29

 [Hz]

16-71

Relay

 Output

 [bin]

16-72

Counter

 A

16-73

Counter

 B

16-75

Analog

 In

 X30/11

16-76

Analog

 In

 X30/12

16-77

Analog

 Out

 X30/8

 [mA]

16-8*

Fieldbus

 &

 FC

 Port

16-80

Fieldbus

 CTW

 1

16-82

Fieldbus

 REF

 1

16-84

Comm.

 Option

 STW

16-85

FC

 Port

 CTW

 1

16-86

FC

 Port

 REF

 1

16-9*

Diagnosis

 Readouts

16-90

Alarm

 Word

16-91

Alarm

 Word

 2

16-92

Warning

 Word

16-93

Warning

 Word

 2

16-94

Ext.

 Status

 Word

16-95

Ext.

 Status

 Word

 2

16-96

Maintenance

 Word

18-**

Info

 &

 Readouts

18-0*

Maintenance

 Log

18-00

Maintenance

 Log:

 Item

18-01

Maintenance

 Log:

 Action

18-02

Maintenance

 Log:

 Time

18-03

Maintenance

 Log:

 Date

 and

 Time

18-1*

Fire

 Mode

 Log

18-10

Fire

 Mode

 Log:

 Event

18-11

Fire

 Mode

 Log:

 Time

18-12

Fire

 Mode

 Log:

 Date

 and

 Time

18-3*

Inputs

 &

 Outputs

18-30

Analog

 Input

 X42/1

18-31

Analog

 Input

 X42/3

18-32

Analog

 Input

 X42/5

18-33

Analog

 Out

 X42/7

 [V]

18-34

Analog

 Out

 X42/9

 [V]

18-35

Analog

 Out

 X42/11

 [V]

18-36

Analog

 Input

 X48/2

 [mA]

18-37

Temp.

 Input

 X48/4

18-38

Temp.

 Input

 X48/7

18-39

Temp.

 Input

 X48/10

18-5*

Ref.

 &

 Feedb.

18-50

Sensorless

 Readout

 [unit]

20-**

Drive

 Closed

 Loop

20-0*

Feedback

20-00

Feedback

 1

 Source

20-01

Feedback

 1

 Conversion

20-02

Feedback

 1

 Source

 Unit

20-03

Feedback

 2

 Source

20-04

Feedback

 2

 Conversion

20-05

Feedback

 2

 Source

 Unit

20-06

Feedback

 3

 Source

20-07

Feedback

 3

 Conversion

20-08

Feedback

 3

 Source

 Unit

20-12

Reference/Feedback

 Unit

20-13

Minimum

 Reference/Feedb.

20-14

Maximum

 Reference/Feedb.

20-2*

Feedback/Setpoint

20-20

Feedback

 Function

20-21

Setpoint

 1

20-22

Setpoint

 2

20-23

Setpoint

 3

20-3*

Feedb.

 Adv.

 Conv.

20-30

Refrigerant

20-31

User

 Defined

 Refrigerant

 A1

20-32

User

 Defined

 Refrigerant

 A2

20-33

User

 Defined

 Refrigerant

 A3

20-34

Duct

 1

 Area

 [m2]

20-35

Duct

 1

 Area

 [in2]

20-36

Duct

 2

 Area

 [m2]

20-37

Duct

 2

 Area

 [in2]

20-38

Air

 Density

 Factor

 [%]

20-6*

Sensorless

20-60

Sensorless

 Unit

20-69

Sensorless

 Information

20-7*

PID

 Autotuning

20-70

Closed

 Loop

 Type

20-71

PID

 Performance

20-72

PID

 Output

 Change

20-73

Minimum

 Feedback

 Level

20-74

Maximum

 Feedback

 Level

20-79

PID

 Autotuning

20-8*

PID

 Basic

 Settings

20-81

PID

 Normal/

 Inverse

 Control

20-82

PID

 Start

 Speed

 [RPM]

20-83

PID

 Start

 Speed

 [Hz]

20-84

On

 Reference

 Bandwidth

20-9*

PID

 Controller

20-91

PID

 Anti

 Windup

20-93

PID

 Proportional

 Gain

20-94

PID

 Integral

 Time

20-95

PID

 Differentiation

 Time

20-96

PID

 Diff.

 Gain

 Limit

21-**

Ext.

 Closed

 Loop

21-0*

Ext.

 CL

 Autotuning

21-00

Closed

 Loop

 Type

21-01

PID

 Performance

21-02

PID

 Output

 Change

21-03

Minimum

 Feedback

 Level

21-04

Maximum

 Feedback

 Level

21-09

PID

 Autotuning

21-1*

Ext.

 CL

 1

 Ref./Fb.

21-10

Ext.

 1

 Ref./Feedback

 Unit

21-11

Ext.

 1

 Minimum

 Reference

21-12

Ext.

 1

 Maximum

 Reference

21-13

Ext.

 1

 Reference

 Source

21-14

Ext.

 1

 Feedback

 Source

21-15

Ext.

 1

 Setpoint

21-17

Ext.

 1

 Reference

 [Unit]

21-18

Ext.

 1

 Feedback

 [Unit]

21-19

Ext.

 1

 Output

 [%]

21-2*

Ext.

 CL

 1

 PID

21-20

Ext.

 1

 Normal/Inverse

 Control

21-21

Ext.

 1

 Proportional

 Gain

21-22

Ext.

 1

 Integral

 Time

21-23

Ext.

 1

 Differentation

 Time

21-24

Ext.

 1

 Dif.

 Gain

 Limit

21-3*

Ext.

 CL

 2

 Ref./Fb.

21-30

Ext.

 2

 Ref./Feedback

 Unit

21-31

Ext.

 2

 Minimum

 Reference

21-32

Ext.

 2

 Maximum

 Reference

21-33

Ext.

 2

 Reference

 Source

21-34

Ext.

 2

 Feedback

 Source

21-35

Ext.

 2

 Setpoint

21-37

Ext.

 2

 Reference

 [Unit]

21-38

Ext.

 2

 Feedback

 [Unit]

21-39

Ext.

 2

 Output

 [%]

21-4*

Ext.

 CL

 2

 PID

21-40

Ext.

 2

 Normal/Inverse

 Control

21-41

Ext.

 2

 Proportional

 Gain

21-42

Ext.

 2

 Integral

 Time

21-43

Ext.

 2

 Differentation

 Time

21-44

Ext.

 2

 Dif.

 Gain

 Limit

21-5*

Ext.

 CL

 3

 Ref./Fb.

21-50

Ext.

 3

 Ref./Feedback

 Unit

21-51

Ext.

 3

 Minimum

 Reference

21-52

Ext.

 3

 Maximum

 Reference

21-53

Ext.

 3

 Reference

 Source

21-54

Ext.

 3

 Feedback

 Source

21-55

Ext.

 3

 Setpoint

21-57

Ext.

 3

 Reference

 [Unit]

21-58

Ext.

 3

 Feedback

 [Unit]

21-59

Ext.

 3

 Output

 [%]

21-6*

Ext.

 CL

 3

 PID

21-60

Ext.

 3

 Normal/Inverse

 Control

21-61

Ext.

 3

 Proportional

 Gain

21-62

Ext.

 3

 Integral

 Time

21-63

Ext.

 3

 Differentation

 Time

21-64

Ext.

 3

 Dif.

 Gain

 Limit

22-**

Appl.

 Functions

22-0*

Miscellaneous

22-00

External

 Interlock

 Delay

22-01

Power

 Filter

 Time

22-2*

No-Flow

 Detection

22-20

Low

 Power

 Auto

 Set-up

22-21

Low

 Power

 Detection

22-22

Low

 Speed

 Detection

22-23

No-Flow

 Function

22-24

No-Flow

 Delay

22-26

Dry

 Pump

 Function

22-27

Dry

 Pump

 Delay

22-3*

No-Flow

 Power

 Tuning

22-30

No-Flow

 Power

22-31

Power

 Correction

 Factor

22-32

Low

 Speed

 [RPM]

22-33

Low

 Speed

 [Hz]

22-34

Low

 Speed

 Power

 [kW]

22-35

Low

 Speed

 Power

 [HP]

22-36

High

 Speed

 [RPM]

22-37

High

 Speed

 [Hz]

22-38

High

 Speed

 Power

 [kW]

22-39

High

 Speed

 Power

 [HP]

22-4*

Sleep

 Mode

22-40

Minimum

 Run

 Time

22-41

Minimum

 Sleep

 Time

22-42

Wake-up

 Speed

 [RPM]

22-43

Wake-up

 Speed

 [Hz]

22-44

Wake-up

 Ref./FB

 Difference

22-45

Setpoint

 Boost

22-46

Maximum

 Boost

 Time

22-5*

End

 of

 Curve

22-50

End

 of

 Curve

 Function

22-51

End

 of

 Curve

 Delay

22-6*

Broken

 Belt

 Detection

22-60

Broken

 Belt

 Function

22-61

Broken

 Belt

 Torque

22-62

Broken

 Belt

 Delay

22-7*

Short

 Cycle

 Protection

22-75

Short

 Cycle

 Protection

22-76

Interval

 between

 Starts

22-77

Minimum

 Run

 Time

22-78

Minimum

 Run

 Time

 Override

22-79

Minimum

 Run

 Time

 Override

 Value

22-8*

Flow

 Compensation

22-80

Flow

 Compensation

22-81

Square-linear

 Curve

 Approximation

22-82

Work

 Point

 Calculation

22-83

Speed

 at

 No-Flow

 [RPM]

22-84

Speed

 at

 No-Flow

 [Hz]

22-85

Speed

 at

 Design

 Point

 [RPM]

22-86

Speed

 at

 Design

 Point

 [Hz]

22-87

Pressure

 at

 No-Flow

 Speed

22-88

Pressure

 at

 Rated

 Speed

22-89

Flow

 at

 Design

 Point

22-90

Flow

 at

 Rated

 Speed

23-**

Time-based

 Functions

23-0*

Timed

 Actions

23-00

ON

 Time

23-01

ON

 Action

23-02

OFF

 Time

23-03

OFF

 Action

23-04

Occurrence

23-0*

Timed

 Actions

 Settings

23-08

Timed

 Actions

 Mode

23-09

Timed

 Actions

 Reactivation

23-1*

Maintenance

23-10

Maintenance

 Item

23-11

Maintenance

 Action

23-12

Maintenance

 Time

 Base

23-13

Maintenance

 Time

 Interval

23-14

Maintenance

 Date

 and

 Time

23-1*

Maintenance

 Reset

23-15

Reset

 Maintenance

 Word

23-16

Maintenance

 Text

23-5*

Energy

 Log

23-50

Energy

 Log

 Resolution

23-51

Period

 Start

23-53

Energy

 Log

23-54

Reset

 Energy

 Log

23-6*

Trending

23-60

Trend

 Variable

VLT

®

 HVAC Drive 

Quick Reference Guide

Содержание EPS VLT

Страница 1: ...MAKING MODERN LIVING POSSIBLE Quick Reference Guide VLT HVAC Drive ...

Страница 2: ...NPN D IN OUT 0V 24V 29 24V NPN 0V PNP 0V PNP 24V NPN 33 D IN 32 D IN 1 2 ON S201 ON 2 1 S202 ON 0 20mA OFF 0 10V 95 400Vac 2A P 5 00 R 82 R 81 37 D IN 130BA544 11 P RS 485 68 N RS 485 69 COM RS 485 61 0V 5V S801 RS 485 RS 485 2 1 ON S801 3 Phase power input DC bus Switch Mode Power Supply Motor Analog Output Interface relay1 relay2 ON Terminated OFF Open Brake resistor NPN Sink PNP Source Illustra...

Страница 3: ... and variables defined or chosen by the user By pressing the Status key up to one extra line can be added c Status line Status messages displaying text Auto on Reset Hand on Off Status Quick Menu Main Menu Alarm Log B a c k C a n c e l Info OK Status 1 0 1234rpm 10 4A 43 5Hz Run OK 43 5Hz On Alarm Warn 130BA018 13 1 2 3 4 b a c Illustration 2 1 The display is divided into 3 sections Top section a ...

Страница 4: ...eedb Value 20 00 Feedback 1 Source Q3 12 Clock Settings 5 15 Terminal 33 Digital Input 20 21 Setpoint 1 6 22 Terminal 54 Low Current 20 01 Feedback 1 Conversion 0 70 Date and Time Q3 21 Analog Reference 20 81 PID Normal Inverse Control 6 24 Terminal 54 Low Ref Feedb Value 20 02 Feedback 1 Source Unit 0 71 Date Format 3 02 Minimum Reference 20 82 PID Start Speed RPM 6 25 Terminal 54 High Ref Feedb ...

Страница 5: ... 46 Maximum Boost Time 22 45 Setpoint Boost 22 75 Short Cycle Protection 6 23 Terminal 54 High Current 20 73 Minimum Feedback Level 2 10 Brake Function 22 46 Maximum Boost Time 22 76 Interval between Starts 6 24 Terminal 54 Low Ref Feedb Value 20 74 Maximum Feedback Level 2 16 AC brake Max Current 22 26 Dry Pump Function 22 77 Minimum Run Time 6 25 Terminal 54 High Ref Feedb Value 20 79 PID Autotu...

Страница 6: ...ime 3 52 Ramp 2 Ramp Down Time 3 8 Other Ramps 3 80 Jog Ramp Time 3 81 Quick Stop Ramp Time 3 82 Starting Ramp Up Time 3 9 Digital Pot Meter 3 90 Step Size 3 91 Ramp Time 3 92 Power Restore 3 93 Maximum Limit 3 94 Minimum Limit 3 95 Ramp Delay 4 Limits Warnings 4 1 Motor Limits 4 10 Motor Speed Direction 4 11 Motor Speed Low Limit RPM 4 12 Motor Speed Low Limit Hz 4 13 Motor Speed High Limit RPM 4...

Страница 7: ...lex 12 2 Process Data 12 20 Control Instance 12 21 Process Data Config Write 12 22 Process Data Config Read 12 27 Primary Master 12 28 Store Data Values 12 29 Store Always 12 3 EtherNet IP 12 30 Warning Parameter 12 31 Net Reference 12 32 Net Control 12 33 CIP Revision 12 34 CIP Product Code 12 35 EDS Parameter 12 37 COS Inhibit Timer 12 38 COS Filter 12 4 Modbus TCP 12 40 Status Parameter 12 41 S...

Страница 8: ...erence Bandwidth 20 9 PID Controller 20 91 PID Anti Windup 20 93 PID Proportional Gain 20 94 PID Integral Time 20 95 PID Differentiation Time 20 96 PID Diff Gain Limit 21 Ext Closed Loop 21 0 Ext CL Autotuning 21 00 Closed Loop Type 21 01 PID Performance 21 02 PID Output Change 21 03 Minimum Feedback Level 21 04 Maximum Feedback Level 21 09 PID Autotuning 21 1 Ext CL 1 Ref Fb 21 10 Ext 1 Ref Feedb...

Страница 9: ... Low Ref Feedb Value 26 25 Term X42 3 High Ref Feedb Value 26 26 Term X42 3 Filter Time Constant 26 27 Term X42 3 Live Zero 26 3 Analog Input X42 5 26 30 Terminal X42 5 Low Voltage 26 31 Terminal X42 5 High Voltage 26 34 Term X42 5 Low Ref Feedb Value 26 35 Term X42 5 High Ref Feedb Value 26 36 Term X42 5 Filter Time Constant 26 37 Term X42 5 Live Zero 26 4 Analog Out X42 7 26 40 Terminal X42 7 Ou...

Страница 10: ... measurements The charac teristic is shown in Illustration 2 21 1 2 1 0 1 4 30 10 20 100 60 40 50 1 8 1 6 2 0 2000 500 200 400 300 1000 600 t s 175ZA052 12 fOUT 2 x f M N fOUT 0 2 x f M N fOUT 1 x f M N par 1 23 IMN par 1 24 IM Illustration 2 21 The X axis is showing the ratio between Imotor and Imotor nominal The Y axis is showing the time in seconds before the ETR cuts off and trips the frequenc...

Страница 11: ...e source 55 50 39 42 53 54 R 3 0 k Ω 3 0 k Ω 10V 130BA153 11 PTC Thermistor OFF ON Input Digital analog Supply Voltage V Cut out Values Threshold Cut out Values Digital 24 6 6kΩ 10 8kΩ Digital 10 800Ω 2 7kΩ Analog 10 3 0kΩ 3 0kΩ NOTE Check that the chosen supply voltage follows the specifi cation of the used thermistor element Summary With the Torque limit feature the motor is protected for being ...

Страница 12: ...voltage rating The unit is still active WARNING ALARM 7 DC overvoltage If the intermediate circuit voltage exceeds the limit the frequency converter trips after a time Troubleshooting Connect a brake resistor Extend the ramp time Change the ramp type Activate the functions in 2 10 Brake Function Increase 14 26 Trip Delay at Inverter Fault WARNING ALARM 8 DC under voltage If the intermediate circui...

Страница 13: ...imately 200 of the rated current is exceeded The warning lasts about 1 5 secs then the frequency converter trips and issues an alarm This fault may be caused by shock loading or fast acceleration with high inertia loads If extended mechanical brake control is selected trip can be reset externally Troubleshooting Remove power and check if the motor shaft can be turned Check that the motor size matc...

Страница 14: ...ARNING ALARM 27 Brake chopper fault The brake transistor is monitored during operation and if a short circuit occurs the brake function is disabled and a warning is issued The frequency converter is still operational but since the brake transistor has short circuited substantial power is transmitted to the brake resistor even if it is inactive Remove power to the frequency converter and remove the...

Страница 15: ... WARNING 41 Overload of digital output terminal 29 Check the load connected to terminal 29 or remove short circuit connection Check 5 00 Digital I O Mode and 5 02 Terminal 29 Mode WARNING 42 Overload of digital output on X30 6 or overload of digital output on X30 7 For X30 6 check the load connected to X30 6 or remove the short circuit connection Check 5 32 Term X30 6 Digi Out MCB 101 For X30 7 ch...

Страница 16: ...the ambient temperature of the unit Also a trickle amount of current can be supplied to the frequency converter whenever the motor is stopped by setting 2 00 DC Hold Preheat Current at 5 and 1 80 Function at Stop ALARM 67 Option module configuration has changed One or more options have either been added or removed since the last power down Check that the configuration change is intentional and res...

Страница 17: ...et the frequency converter after the fault has been cleared WARNING 98 Clock fault Time is not set or the RTC clock has failed Reset the clock in 0 70 Date and Time WARNING 200 Fire mode This indicates the frequency converter is operating in fire mode The warning clears when fire mode is removed See the fire mode data in the alarm log WARNING 201 Fire mode was active This indicates the frequency c...