Figure 21: SET button parameter list
SET
Set
V
(PS)
in
cFg
Set
r12
Main switch
o61
Application mode
o06
Temperature sensor type
o02
DI1 Configuration
o37
DI2 Configuration
o03
Network address
M
enu g
roups
See also the f
ollo
wing pages
(Return)
<
V
r--
A--
d--
F--
c--
o--
P--
u--
<
(Return)
SET button
3 s: configuration settings
PS: Access code (if any)
Danf
oss
80G8444
o62
Quick setup
Quick setup – get a good start
With the following procedure you can start regulation very quickly:
Press the “SET” button for 3 seconds and access the parameter menu (display will show “cFg”).
Press the down button “
∨
” to go to “cFg” menu (display will show “cFg”)
Press the right “>” key to open the configuration menu (display will show r12).
Open the “r12 Main switch” parameter and stop control by setting it OFF (Press SET).
Open the “o61 application mode” and select the needed application mode (Press SET).
Open the “o06 Sensor type” and select the temperature sensor type used (n5=NTC 5 K, n10=NTC 10 K, Ptc=PTC,
Pt1=Pt1000) – (Press “SET”).
Open the “o02 DI1 Configuration” and select the function associated to digital input 1 (see
) – (Press “SET”).
Open the “o37 DI2 Configuration” and select the function associated to digital input 2 (see
) – (Press “SET”).
Open the “o62 Quick setting” parameter and select the presetting that fits with the application in use (see
) – (Press “SET”).
Open the "o03 Network address" and set the Modbus address if required
Navigate back to parameter “r12 Main switch” and set it in “ON” position to start control.
Go through the entire parameter list and change the factory settings where needed.
Table 11: Quick setting
Parameter
1
2
3
4
5
6
7
Cabinet MT
Natural def.
Stop on time
Cabinet MT
El. def.
Stop on time
Cabinet MT
El. def.
Stop on temp
Cabinet LT
El. def.
Stop on temp
Room MT
El. def.
Stop on time
Room MT
El. def.
Stop on temp
Room LT
El. def.
Stop on temp
r00 Cut-out
4 °C
2 °C
2 °C
-24 °C
6 °C
3 °C
-22 °C
r02 Max Cut-out
6 °C
4 °C
4 °C
-22 °C
8 °C
5 °C
-20 °C
r03 Min Cut-out
2 °C
0 °C
0 °C
-26 °C
4 °C
1 °C
-24 °C
A13 HighLim Air
10 °C
8 °C
8 °C
-15 °C
10 °C
8 °C
-15 °C
A14 LowLim Air
-5 °C
-5 °C
-5 °C
-30 °C
0 °C
0 °C
-30 °C
d01 Def. Method
Natural
Electrical
Electrical
Electrical
Electrical
Electrical
Electrical
d03 Def.Interval
6 hour
6 hour
6 hour
12 hour
8 hour
8 hour
12 hour
d10 DefStopSens.
Time
Time
S5 Sensor
S5 Sensor
Time
S5 Sensor
S5 Sensor
o02 DI1 Config.
Door fct.
Door fct.
Door fct.
Case controller, type EKC 223 and EKC 224
© Danfoss | Climate Solutions | 2023.05