Name
Terminals
Description
DO1
1,2L
Digital output signal
•
Compressor or Heating element:
There is connection between terminal 1 and 2 when the function is ON.
DO2
3L, 5
Digital output signal
•
Defrost and Light:
There is connection between terminal 3L and 5 when the function is ON.
•
Alarm:
There is connection between terminal 3L and 5 when the function is ON, but via the parameter P75 the alarm
relay action can be inverted.
DO3
3L, 6
Digital output signal
•
Fan and Light:
There is connection between terminal 3L and 6 when the function is ON.
DO4
3L, 7
Digital output signal
•
Light:
There is connection between terminal 3L and 7 when the function is ON.
•
Alarm:
There is connection between terminal 3L and 7 when the function is ON, but via the parameter P75 the alarm
relay action can be inverted.
TTL port
Case controller, type EKC 223 and EKC 224
© Danfoss | Climate Solutions | 2023.05
BC432222569027en-000201 | 14