Then insert replacement filter screen (5), dome side
first.
Screw the dynamic orifice cover plug (16) into
housing with 4 mm Allan key.
Carefully place the “screen mesh” filter (5) dome
first into the PVE housing, followed by the O-rings
(6, 7 and 8).
Remember to use a light grade grease to keep the
O-rings in place.
Service Manual
EH Electro Proportional Hydraulic Valve In-line Version
Reassembly
18