Then insert the PR valve spool (11) ensuring that
the end with the larger opening fits against the
rounded head of the poppet (10). Remember to
lubricate the spool first with a thin film of oil.
Screw in RP retaining plug (12) with
5 mm Allan key.
Make sure O-ring is lubricated.
If your EH valve has a dynamic orifice function then
screw the plug (18) into housing with 2.5 mm
Allan key.
Service Manual
EH Electro Proportional Hydraulic Valve In-line Version
Reassembly
L1026660 • Rev BA • Mar 2014
17