Always connect the thermostat to continuous power 

supply.

• 

Do not expose the thermostat to moisture, water, 

dust, and excessive heat.

Mounting Instructions

Please observe the following placement guidelines:

Place the thermostat at a suitable height on 

the wall (typically 80-170cm.).

In wet rooms, place the thermostat 

according to local regulation on IP classes.

Do not place the thermostat on the inner 

side of an exterior wall.

Содержание ECtemp 130

Страница 1: ...ECtemp 130 Electronic Thermostat Installation Guide electricheating danfoss com ...

Страница 2: ...ECtemp 130 Installation Guide 2 ...

Страница 3: ...ture setting with a scale from 1 to 5 each step corresponds to approximately 9 C Furthermore the thermostat has an LED indicator showing standby periods green light and heating periods red light More information on this product can also be found at ectemp danfoss com Table of Contents 1 Introduction 3 1 1 Technical Specifications 4 1 2 Safety Instructions 5 2 Mounting Instructions 6 3 Settings 10 ...

Страница 4: ...ax 1A Sensing units NTC 15 kOhm at 25 C Sensing values 0 C 25 C 50 C 42 kOhm 15 kOhm 6 kOhm Hysteresis 0 2 C Ambient temperature 0 to 30 C Frost protection temperature 5 C Temperature range 5 45 C Cable specification max 1x4 mm or 2x2 5 mm Ball pressure temperature 75 C Pollution degree Degree 2 domestic use Type 1C Storage temperature 20 to 65 C IP class 30 Protection class Class II ...

Страница 5: ...T When the thermostat is used to control a floor heating element in connection with a wooden floor or similar material always use a floor sensor and never set the maximum floor temperature to more than 35 C Please also note the following The installation of the thermostat must be done by an authorized and qualified installer according to local regulations The thermostat must be connected to a powe...

Страница 6: ...sture water dust and excessive heat 2 Mounting Instructions Please observe the following placement guidelines Place the thermostat at a suitable height on the wall typically 80 170cm In wet rooms place the thermostat according to local regulation on IP classes Do not place the thermostat on the inner side of an exterior wall ...

Страница 7: ... where it is not exposed to sunlight or draft from door openings Equally distant and 2cm from two heat ing cables The conduit should be flush with the floor surface countersink the conduit if necessary Route the conduit to the connection box The bending radius of the conduit must be min 50mm ...

Страница 8: ...elow to mount the thermostat 1 Open the thermostat Lift off the button using a small screwdriver Loosen the screw which holds the front Push down the release tab at the top of the thermostat using a flat object while slowly pulling off the front cover ...

Страница 9: ...for fastening the thermostat 3 Connect the thermostat according to the connectiondiagram IP30 0T30 D130 NTC 1 2 3 4 Sensor Max Load 16 1 A Mains 220 240V N LOAD L LOAD N L The screen of the heating cable must be connected to the earth conductor of the power supply cable by using a separate connector Note Always install the floor sensor in a conduit in the floor ...

Страница 10: ...t off the adjustment button using a thin screwdriver 1 2 Move the pins to the desired positions 2 and 3 3 Put the adjustment button back in place Please be aware of the following The floor temperature is measured where the sensor is placed The temperature of the bottom of a wooden floor can be up to 10 degrees higher than the top Floor manufactures often specify the max temperature on the top surf...

Страница 11: ...fault the maximum floor temperature is set to 35 C Always use a floor sensor or a room floor sensor combination to control floor heating Without a floor sensor the temperature control may be less accurate and you risk overheating the floor ...

Страница 12: ...proximate setting for 25 C floor temperature 0 05 8 mm HDF based laminate 800 kg m 28 C 0 10 14 mm beech parquet 650 800 kg m 31 C 0 13 22 mm solid oak plank 800 kg m 32 C 0 17 Max carpet thickness suit able for floor heating acc to EN 1307 34 C 0 18 22 mm solid fir planks 450 650 kg m 35 C ...

Страница 13: ...ECtemp 130 13 Installation Guide ...

Страница 14: ... and in accordance with the instructions the fault is submitted to the installer or the seller without undue delay and proof of purchase is provided Please note that the WARRANTY CERTIFICATE must be filled in stamped and signed by the authorized installer performing the installation Installation date must be indicated After the installation is performed store and keep the WARRANTY CERTIFICATE and ...

Страница 15: ...ion Guide WARRANTY CERTIFICATE The Danfoss warranty is granted to Address Stamp Purchase date Serial number of the product Product Art No Connected output W Installation Date Signature Connection Date Signature Not mandatory ...

Страница 16: ...ECtemp 130 Installation Guide 16 5 Disposal Instruction ...

Страница 17: ...ECtemp 130 17 Installation Guide ...

Страница 18: ...ECtemp 130 Installation Guide 18 ...

Страница 19: ...Danfoss ECtemp 130 Produced by Danfoss 03 2023 08091360 AQ059486452134en 010203 Danfoss A S Nordborgvej 81 6430 Nordborg Syddanmark Denmark ...

Страница 20: ...ECtemp 130 088L0030 220 240V 50 60Hz 5 to 45 C 16A 3680W 230V IP 30 Designed in Denmark for Danfoss A S Product Documentation 08091360 d ...

Отзывы: