background image

AN324050550815en-000201 | 19

Danfoss © | 2020.07

Installation Guide 

 

Danfoss ECdry Touch Kit

1�1 

Laying the top floor

Please consult the floor manufacturer to 

ensure that the floor covering is suitable for 

floor heating. The final floor covering (lami-

nate or parquet) can be laid when the ECdry 

heating system has been tested.  

According to ISO 13732-2, 

the comfortable floor sur-

face temperature depends 

on the flooring material. 

Soft wood (pine)

22.5 - 28°C
Hard wood (oak)

24.5 - 28°C

However, observe the maximum floor 

surface temperature according to the floor-

ing manufacturer. For most wooden floor 

products, the temperature is usually around 

27 °C. All temperature settings must be set 

some degrees higher to compensate for the 

heat resistance in the top flooring.

Thermal 

resistance

[m²K/W]

Examples of Flooring

Details

Approximate setting 

for 25°C 

floor temperature

0,07

11 mm HDF based laminate

> 800 kg/m³

28°C

0,10

14 mm beech parquet

650 - 800 kg/m³

31°C

0,13

22 mm solid oak plank

> 800 kg/m³

32°C

0.18

22 mm solid fir planks

450 - 650 kg/m³

35°C

1�1 

Warning label

The warning label that is included in the 

ECdry Touch Kit must be filled out and 

placed in the distribution board. For future 

reference it is important to fill in, which 

room and how many ECdry elements that 

have been installed, by whom and the 

installation date. Furthermore, the room 

should be drawn in the manual so it is easy 

to see how the elements have been posi-

tioned in the room in the future.  See layout 

paper on next page.

Содержание ECdry 100

Страница 1: ...Danfoss ECdry Touch Kit Installation Guide...

Страница 2: ......

Страница 3: ...1 1 Preparing the base 13 1 1 Calculating current limitations 14 1 1 Connecting the ECdry elements 15 1 1 Cutting the ECdry floor heating element to size 16 1 1 Filling up the remaining space 17 1 1...

Страница 4: ...ystem We are confident that you will be satisfied with your new system Danfoss brings you optimum comfort with the luxury and comfort of a warm floor as well as a pleasant room temperature Floor heati...

Страница 5: ...products ECdry has been tested and approved with flooring materials with insulation values from 0 07 to 0 18 m K W For best performance of the floor heating sys tem keep the insulation value from the...

Страница 6: ...nderfloor heating system it will be most effective if the underfloor is well insulated The following directions will guide you step by step through the installation process Please read the directions...

Страница 7: ...AN324050550815en 000201 7 Danfoss 2020 07 Installation Guide Danfoss ECdry Touch Kit 3 Product overview ECdry FM ECdry Connection Tool ECdry Tape ECdry X ECdry End Stop ECdry Protection Cap...

Страница 8: ...dry 100 ECdry Element 1 5 m Accessories ECdry Name Description ECdry Touch Kit ECdry Touch Kit ECtemp Touch Electronic Intelligent Timer Thermostat ECtemp NTC Floor Sensor ECdry Connection Tool ECdry...

Страница 9: ...Sound reduction value 17 dB Insulation value 8 W m K Maximum heated surface per ECdry Touch Kit Maximum current limit is 10 Ampere Product Max heated surface ECdry 55 42 m ECdry 100 23 m For ECdry 55...

Страница 10: ...e no electrical parts in this area E M A K The ECdry element can NOT be cut here as there are electrical parts in this area E M A K For indoor use only E M A K Read the instruction manual before insta...

Страница 11: ...All ECdry floor heating mats are one metre wide and the standard length varies from one to five me tres Reduce the length of the elements to the required size as shown in the table Example 1 When the...

Страница 12: ...id hot spots by ensuring that the heat from the floor heating is homogeneously released to the area you wish to heat and that there is free space ventilation under the furniture When designing the lay...

Страница 13: ...you start installing the product please ensure that the floor is Permanently inflexible Dry Flat and regular Dust and fat free Free from any sharp objects Use a powerful vacuum cleaner to remove all d...

Страница 14: ...A 4 m 3 4 m 187 Watt 0 81 A 5 m 4 4 m 242 Watt 1 05 A For ECdry 100 Floor area Heated surface Total power output Ampere 1 m 0 4 m 40 Watt 0 17 A 2 m 1 4 m 140 Watt 0 61 A 3 m 2 4 m 240 Watt 1 04 A 4...

Страница 15: ...tion fits correctly and permanently Continue with the subse quent elements in the same manner Make sure that all plug in connections fit straight and without any mechanical stress Discontinue the floo...

Страница 16: ...de The ECdry heating element may only be cut at the far ends where there are no electrical parts inside as marked on the product below Markings and symbols have been printed on the ECdry heating mats...

Страница 17: ...rical parts and ensuring a straight cut To be certain that the distribution of the floor heating mats in your room is correct we suggest you make everything fit before you secure the elements permanen...

Страница 18: ...iller material Minimum bending diameter is 5 cm To place the sensor in the right spot remove the cut away area in the ECdry Touch heating element and place the sensor down into the groove Fix the sens...

Страница 19: ...l temperature settings must be set some degrees higher to compensate for the heat resistance in the top flooring Thermal resistance m K W Examples of Flooring Details Approximate setting for 25 C floo...

Страница 20: ...0550815en 000201 Installation Guide Danfoss ECdry Touch Kit 6 Layout paper Please draw the room on the page below and position the heating mats that you are installing for future reference These produ...

Страница 21: ...e RAL 9010 2 Included into the ECdry Touch Kit 1 Contains languages Bulgarian Czech Danish English Estonian Finnish French German Latvian Lithuanian Norwegian Polish Romanian Russian Slovenian Slovak...

Страница 22: ...against a wall in vertical position Do not install or use the floor heating system after one or more components have been damaged Do not allow home repairs under any circumstances Repairs must be car...

Страница 23: ...ord is damaged it must be replaced by the manufacturer its service agent or similar persons in order to avoid a hazard Connect the floor heating to 230 Volt and 50 Hz only Do not allow needles sharp o...

Страница 24: ...e faulty by reason of defective design materials or workmanship Repair or replace ment shall be carried out solely at Danfoss s discretion Danfoss shall not be liable for any consequential or incident...

Страница 25: ...Certificate The Danfoss Warranty certificate is granted to Name Address City Country Telephone Attention The Warranty Certificate must be completed correctly for the Warranty to be valid Please read t...

Страница 26: ...26 Danfoss 2020 07 AN324050550815en 000201 Installation Guide Danfoss ECdry Touch Kit...

Страница 27: ...AN324050550815en 000201 27 Danfoss 2020 07 Installation Guide Danfoss ECdry Touch Kit...

Страница 28: ...Danfoss A S Nordborgvej 81 6430 Nordborg Syddanmark Denmark Danfoss 2020 07 08091477 AN324050550815en 000201...

Отзывы: