regularly, the water tank might be damaged. It is quite normal that the
safety valve lets out small amounts of water when the water tank is being
charged, especially if a lot of hot water was used previously.
Both safety valves can be checked by turning the cap a quarter of a turn
clockwise until the valve lets out some water through the overflow pipe.
If a safety valve does not work properly, it must be replaced. Contact your
installer.
The opening pressure of the safety valves is not adjustable.
3.5
In the event of leakage
In the event of leakage in the hot water pipes between the unit and water
taps, close the shut-off valve on the cold water inlet immediately. Contact
your installer, see References, Page 28.
In the event of leakage in the brine circuit, turn off the heat pump and call
your installer immediately, see References, Page 28.
16 – User manual
VUIFM102
Содержание DHP-S 7Ua
Страница 1: ...User manual DHP S DP VUIFM102 ...
Страница 4: ......
Страница 31: ...System adjustment Tel No User manual VUIFM102 29 ...
Страница 32: ...VUIFM102 ...