N
During the unit installation make first refrigerant connections and
then electrical connections. If unit is uninstalled first disconnect elec-
trical cables, then refrigerant connections.
N
Connect the Air to water heat pump to grounding system before per-
forming the electrical connection.
N
When installing the unit, you shouldn't use inter connection wire.
6.17.1
Between indoor unit and outdoor unit connection cable specifications (Common in use)
Communication cable
Home server
0.75mm², 2wires
0.75mm², 2wires
▪
For the power Cable, use the grade H07RN-F or H05RN-F materials.
When installing the indoor unit in a computer room or network room, use the double shielded (Tape aluminum / polyester braid + cop-
per ) cable of FROHH2R type.
6.17.2
1 Phase terminal block spec
5 kW
N
L
2(N)
1(L)
11.4
10.1
10.1
11.4
AC power : M5 screw
Communication : M4 screw