59
VMBMA602
Menu selection
Meaning
Factory setting
ALARM
(Expansion card)
0 = stop signal on output External alarm
1 = start signal on output External alarm
-
SHUNT COOLING
(Expansion card)
- = shuts shunt
0 = shunt unaffected
+ = opens shunt
-
SHUNTGROUP
(Expansion card)
- = shuts shunt
0 = shunt unaffected
+ = opens shunt
-
COOLING PASSIVE
(Expansion card)
0 = stop passive cooling
1 = start passive cooling (brine pump starts and shunt cooling regulates to set
point value)
-
HGW-SHUNT
(DHP-H Opti Pro)
- = shuts shunt
0 = shunt unaffected
+ = opens shunt
-
COOLING ACTIVE
(Expansion card)
0 = stop active cooling
1 = start active cooling (brine pump and compressor starts, shunt cooling regu-
lates to set point value)
-
VXV POOL
(Expansion card)
0 = normal mode for exchange valve
1 = pool mode for exchange valve
-
0-10V
(Expansion card)
For any future demands.
-
Sub menu SERVICE -> INSTALLATION
Used for settings that are set during installation
Menu selection
Meaning
Factory setting
SWEDISH
Language setting for the control computer.
SWEDISH
(SVENSKA
NORSK,
SUOMI,
DEUTSCH,
NEDERLANDS,
ENGLISH,
FRANCAIS
POLSKI
DANSK)
SYSTEM
NOTE! The menu selec-
tion in the SYSTEM menu
varies depending on the
selected values. Tip: start
in the top menu and
work downwards.
Sub menu SERVICE -> INSTALLATION -> SYSTEM:
Menu selection
Meaning
HEAT SOURCE
GROUND OR ROCK
OUTSIDE AIR
Menu selection
Meaning
DIRECT EVAPURATION
BRINE SOLUTION
HEATING SYSTEM
VL-SYSTEM
D-SYSTEM
VLD-SYSTEM (appears if OUTSIDE AIR is selected)
COOLING
(Expansion card)
PASSIVE COOLING: /EXTERNAL/INTEGRATED IN HP
ACT COOLING: /EXTERNAL
ROOM SENSOR: 0/1 (Appears if room sensor is installed)
(0=controls to a constant value, 1=controls to the value that the room sensor has)
(The menu option INTEGRATED IN HP only applies to the DHP-C* heat pump)
POOL
(Expansion card)
ON /
Does not appear if SHUNT GROUP is selected.
SHUNTGROUP
(Expansion card)
ON /
When ON, HEAT CURVE 2 is activated in the INFORMATION menu. Not displayed if
POOL is selected.
ADD. HEAT
0-10V: / EXTERNAL ADDITIONAL HEATER (Expansion card)
FLOW SENSOR: ON /
CURRENT LIMITER: ON / (Expansion card)
PHASE FAULT: / PHASE READING