DHP-AX – 29
VUBMI102
Sub-menu DEFROST
5.1.6
In the “DEFROST” menu it is possible to view miscel-
laneous information about defrosting the outdoor
unit and also possible to make adjustments.
Menu text
Description
Adjusted by:
DEFROSTS
Total number of defrosts carried out since
installation, i.e. the number not reset.
Not adjustable
BETW. 2 DEFR
The operating time of the compressor in
minutes between the 2 last defrosts.
Not adjustable
TIME LAST DEFR
The operating time of the compressor in
minutes since last defrost. Reset after a
defrost is completed.
Not adjustable
DEFROST CURVE
Here, the angle of the defrost curve can
be changed using the right-hand arrow
and by either pr or -. (Change
the start temperature for when defros-
ting is to begin).
By the customer, if
necessary.
MANUAL DEFR
By using the right-hand arrow and
then pr, defrost can be started
manually. During defrost, hot refrigerant
circulates to the air heat exchanger.
By the customer, if
necessary.
DEFROSTS
BETW. 2 DEFR
TIME LAST DEFR
FAN H OFF AT
DEFROST CURVE
MANUAL DEFR
0S
0M
0M
12°C
0
DEFROST