4

Control system

The heat pump has an integrated control system which automatically calculates the heat or cooling demands in the house to ensure

desired temperature.

The operator panel has a keypad (4) for user interaction and the information is presented in a display (1) above the keypad (4) and by the

indicator (2) beside the power ON/OFF button (3).

1

2

3

4

 

C

C

Fig. 1: Operator panel

1

Information symbols

2

Indicator

3

Power ON/OFF button

4

Keypad

4.1

Keypad

The keypad is used to navigate through the different menus, to select features and lock / unlock the user settings

10

1

2

3

4

5

6

7

8

9

Fig. 2: Keypad buttons

1

Heating/cooling switch

2

Down

3

Up

4

House heating/cooling (function on/off)

5

Clock

6

Lock/unlock

7

Timer on

8

Timer off

9

Domestic hot water (function on/off)

10

Internal electrical heater

4.2

Indicator

The indicator next to the power ON/OFF button on the operator panel is lit green when power is supplied and the operator panel is

connected to the heat pump. When the heat pump is started (using the power button), it is confirmed by a symbol on the display.

User Guide

DHP-AT

Danfoss Heating Solutions

VUGFC20202

9

Содержание DHP-AT

Страница 1: ...MAKING MODERN LIVING POSSIBLE User Guide DHP AT www heating danfoss com...

Страница 2: ...The English language is used for the original instructions Other languages are a translation of the original instructions Directive 2006 42 EC 2011 Copyright Danfoss A S...

Страница 3: ...nterface 13 7 2 Changing operation mode 13 7 3 Adjusting DHW temperature 13 7 4 Changing heat curve and desired room temperature 13 7 5 Setting current time 14 7 6 Timer settings 14 7 7 Changing mode...

Страница 4: ...ronment It is a safe and convenient solution that provides heating hot wa ter and in certain cases cooling for your home at a low cost We thank you for the confidence that you have shown in us by buyi...

Страница 5: ...ter and electrical installations The safety valve Do not make any constructions installations that may affect the operational safety of the heat pump 2 3 Safety valve The following safety precautions...

Страница 6: ...ella prevention Most of these functions are automatically controlled by the control system according to the need from the household or ambient tem peratures Cooling must be initiated manually from the...

Страница 7: ...ill produce a constant supply line temperature following the setting in the control system The picture below shows a simplified view of the recommended heating curves and the temperature working range...

Страница 8: ...n There is an automatic legionella prevention when the heat pump function is set to DHW The automatic legionella prevention runs at 00 00 every 7 th day of operation The water in the hot water tank wi...

Страница 9: ...pad is used to navigate through the different menus to select features and lock unlock the user settings 10 1 2 3 4 5 6 7 8 9 Fig 2 Keypad buttons 1 Heating cooling switch 2 Down 3 Up 4 House heating...

Страница 10: ...hange The following information is available C C 16 17 13 1 2 3 4 5 6 7 8 9 10 11 12 14 15 1 Heating 2 Cooling 3 Defrosting 4 Internal electrical heater 5 Alarm 6 House heating 7 Domestic Hot Water DH...

Страница 11: ...elow C C Viewing other settings Other settings in the control system can be reviewed by navigating through the 25 available menus 1 To enter a menu press for 5 seconds The menu and parameter digits st...

Страница 12: ...is connected to the mains via a safety switch circuit breaker The indicator 2 on the operator panel is lit green when the operator panel is powered on and connected to the control system If the heat p...

Страница 13: ...pressing on the keypad more than 5 seconds stops the DHW production and puts the heat pump in house heating operational mode N The value shown in the display is the present tap water temperature Press...

Страница 14: ...nute setting 5 Before the flashing stops press again or wait 5 seconds to save the settings 7 6 Timer settings The heat pump can start and stop according to timer settings in the control system Settin...

Страница 15: ...ature with the or buttons 2 Press again to return to idle state 7 9 Manual defrosting Manual defrosting should only be initiated when the automatic defrosting function is not sufficient heavy icing on...

Страница 16: ...tomatic legionella protection function 1 1 Activated 0 Deactivated 15 Internal electrical heater start option 0 0 Auto 1 Air temperature condition set in menu 16 2 Water temperature condition set in m...

Страница 17: ...rotection 12 Supply water temperature too high 13 Supply water temperature too low 14 Return gas temperature sensor T5 failure 15 Exhaust gas temperature sensor T4 failure 16 Exhaust gas temperature o...

Страница 18: ...alves is not adjustable 8 4 Cleaning strainer N The heat pump must be switched off at the external main switch before cleaning can be started N The strainer must be cleaned twice a year after installa...

Страница 19: ...radiator valves Leak test Electrical Installation Circuit breaker Fuse Commissioning Bleeding Settings control system Manual test components Manual test different operating conditions Noise check Fun...

Страница 20: ...Settings and adjustments Regular checks Reference to service requirement Warranties and insurances User Guide DHP AT VUGFC20202 Danfoss Heating Solutions 20...

Страница 21: ...Volume of brine litres Pipe installation Company Contact person Telephone number Electrical installation Company Contact person Telephone number Commissioning Company Contact person Telephone number...

Страница 22: ...company Service technician s signature Date year month day Customer s signature Comments Service company Service technician s signature Date year month day Customer s signature Comments Service compa...

Страница 23: ...User Guide DHP AT Danfoss Heating Solutions VUGFC20202 23...

Страница 24: ...he right to alter its products without notice This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications...

Отзывы: