Piping installation
⚠
NOTE! To prevent leaks ensure that there are no stresses in
the connecting pipes!
⚠
NOTE! It is important that the heating system is completely
bled after installation.
⚠
NOTE! Bleed valves must be installed where necessary.
• Ensure that the piping installation follows the dimension and
connection diagrams in section “Heat pump information”.
• Piping installation must be carried out in accordance with appli
-
cable local rules and regulations. The hot water tank must be
equipped with an approved safety valve (supplied).
11
4
5
7
7
12 13 14
16
15
1
17
18
6
2
10
9
3
8
1
2
3
4
5
6
7
8
9
10
11 12
13
14
Mixer valve
Strainer
Bleed valve at stainless
steel water heater
Bleed valve
Safety valve 9 bar
Filler cock
Safety valve (not included)
Heat pump
Water heater
Pipe connections in image:
2 Water heater, return pipe
4 Heating system supply pipe
5 Heating system return pipe
8 Heating system, return pipe
9 Bleed valve, at stainless steel water heater
11 Tap hot water
12 Cold water
13 Water heater, supply pipe to TWS coil
Figure 19: Principle solution for a pipe installation.
Figure 20: General connection diagram.
Position Name
1
Heat pump
2
Supply pipe
3
Return pipe
4
Safety valve (not included)
5
Expansion tank (not included)
6
Strainer
7
Flexible hoses
8
Bleed valve
9
Mixer valve
10
Exchange valve
11
Safety valve (9 bar)
12
Vacuum valve
13
Non-return valve
14
Shut-off valve
15
Cold water
16
Hot water
17
Water heater
18
Bleed valve at stainless steel water heater
5.1
Connection diagram