background image

25

INSTALLATION GUIDE

DEVIreg™ Room

DEVI Control App: 

DEVI Control App User Guide:

 

REFERENCE TO APP MANUAL

To pair the thermostat with the app, initiate the app and follow the 
instructions provided in the app.

App enabled functions

•  wizard assisted installation 

scheduling 

•  pre-heating (adaptive heating) 
•  thermostat limits adaptation 
•  control mode changeability
•  child lock 

•  settings lock 
•  warning and error readout 
•  information export 
•  help function 
•  complete overview of data and 

functions

Содержание DEVIreg Room 140F1161

Страница 1: ...Installation Guide DEVIreg Room Intelligent electronic timer controlled thermostat with App control EN...

Страница 2: ......

Страница 3: ...ble of contents 1 Introduction 4 2 Standard Compliance 5 3 Safety instruction 6 4 Installation Guidelines 7 5 User Guide 17 DEVI Control App 25 DEVI Control App User Guide 25 6 Eco Design Sheet 29 7 W...

Страница 4: ...sed for control of total heating as well as comfort heating of the room The thermostat supports a selection of commonly used frame systems for 55x55 inner geometry framing systems Among others the the...

Страница 5: ...thermostat EN 301 349 1 and EN 301 349 17 EMC standard for radio equipment operating in the 2 4 GHz band EN 300 328 Efficient use of radio spectrum for radio equipment operating in the 2 4 GHz band SI...

Страница 6: ...mendations Electrical heating thermostats must always be installed according to local building regulations and wiring rules Installation must be carried out by an authorized and or qualified installer...

Страница 7: ...at are present on our YouTube channel 4 Installation Guidelines Follow these guidelines when placing the thermostat Install the thermostat in a suitable height on the wall typical 80 170 cm Do not pla...

Страница 8: ...ostat must not be installed in direct wet areas Zones 0 1 and 2 Always follow local regulations regarding IP classes this doesn t mean that the thermostats can t be installed in bathrooms Do not posit...

Страница 9: ...pc Frame 1 pc Frame adapter 1 pc Spacer and 1 pc wire sensor along with the instructions written in local official language 2 Place the floor sensor in the Flexpipe and make sure the sensor element is...

Страница 10: ...m located at a representative position 5 For thin floor constructions the Flexpipe should be flush with the sub floor surface countersink the Flexpipe if possible For thicker constructions the Flexpip...

Страница 11: ...ll pole disconnect 7 Connect the wires according to the wiring diagram on back of the power supply of the thermostat Ensure that the terminals are properly fastened and wires are securely connected 8...

Страница 12: ...ing to the arrow 10 Attach the frame and the Top frame to the thermostat After that attach the thermostat to the Power supply unit by a softly press until all parts firmly connected 11 Carefully attac...

Страница 13: ...stat does not require any settings to be performed in the app however this will be required to modify advanced features schedules and more 14 Dismount thermostat front for replacement Perform steps 11...

Страница 14: ...14 INSTALLATION GUIDE DEVIreg Room Connection scheme DEVIreg Room Room t sensor Load max 16 A NTC 15 kOhm at 25 C sensor adaptation possible...

Страница 15: ...15 k 25 C 3 m default Control PWM Pulse Width Modulation Temperature control range Room temperature 15 C to 35 C Floor temperature 5 C to 35 C 45 C after breakout Ambient temperature range 0 C to 35...

Страница 16: ...Ball pressure test 75 C Storage temperature 25 C to 60 C Timer functions 3 periods per day Resolution of timer is 30 minutes Timer backup for 1 hour Dimensions 85 mm x 85 mm x 20 24 mm in wall depth 2...

Страница 17: ...N GUIDE DEVIreg Room 5 User Guide Product interface Temperature adjustment Indicator OFF Timer schedule App communication Frost protection Whenknobisintempadjustmentmodethethermostatwillnotrunthetimes...

Страница 18: ...t By turning the knob clockwise the temperature will increase User interface daily use On the thermostat the temperature can be directly adjusted using the knob dial by setting the indicator on the wa...

Страница 19: ...ule App communication the app can only display limited information in OFF the app and thermostat will be completely OFF and nothing will be indicated or communicated to the app To pair the thermostat...

Страница 20: ...oduct these will light up when needed Indicators inside the knob All indicators fade out after a duration default 20 seconds unless an error is present Additionally indicators will wake up upon manual...

Страница 21: ...he indicator fades out The indicator flashes red when an error is present this will persist until error is alleviated heating will not be activated activatable Data communication This indicator flashe...

Страница 22: ...The warning will be present until App communication is activated however the indicator will only flash for a duration default 20 seconds Warnings will be displayed in the App Default settings and out...

Страница 23: ...rform a factory reset All indicators will flash briefly to inform about successful factory reset The thermostat will briefly be rebooting please allow for up to 5 seconds for the thermostat to be back...

Страница 24: ...mode needs to be set in the app after the action has been performed To best perform the action the thermostat unit needs to be dismounted from the power supply on the back of the thermostat there is...

Страница 25: ...p initiate the app and follow the instructions provided in the app App enabled functions wizard assisted installation scheduling pre heating adaptive heating thermostat limits adaptation control mode...

Страница 26: ...ock is enable and the user tries to change the setpoint or mode with the potentiometer or encoder W5 Set temperature not achievable Warning given when the room floor temperature from schedule or manua...

Страница 27: ...act installer or local Danfoss service The thermostat requires a restart to operate again Thermostat overheated E3 Thermostat is overheat ed heating is turned off Wait until thermostat cools down The...

Страница 28: ...etected as defective Contact installer or local Danfoss service The potentiometer is reading a value that is outside of the given range Invalid com munication E10 Bluetooth communi cation error Retry...

Страница 29: ...duct is prefilled please fill any all blank slots Information requirements for electric local space heaters Model identifier s DEVIreg Room Item Sym bol Value Unit Item Unit Heat output Type of heat i...

Страница 30: ...consumption fan assisted heat output yes no At nominal heat output elmax 0 00062 kW Type of heat output room temperature control select one At minimum heat output elmin 0 00062 kW single stage heat ou...

Страница 31: ...ol no electronic room temperature control plus day timer no electronic room temperature control plus week timer yes Other control options multiple selections possible room temperature control with pre...

Страница 32: ...TION GUIDE DEVIreg Room with distance control option no with adaptive start control yes with working time limitation no with black bulb sensor no Contact details Danfoss A S Nordborgvej 81 6430 Nordbo...

Страница 33: ...arranty period Danfoss shall offer a new comparable product or repair the product if the product is found to be faulty by reason of defective design materials or workmanship The decision to either rep...

Страница 34: ...hase documents invoice receipt or similar during the whole warranty period DEVIwarranty shall not cover any damage caused by incorrect conditions of use incorrect installation or if installation has b...

Страница 35: ...EVIreg Room WARRANTY CERTIFICATE The DEVIwarranty is granted to Address Stamp Purchase date Serial number of the product Product Art No Connected output W Installation Date Signature Connection Date S...

Страница 36: ...at it may not be disposed of as household waste It must be handed over to the applicable take back scheme for the recycling of electrical and electronic equipment Dispose of the product through channe...

Страница 37: ...37 INSTALLATION GUIDE DEVIreg Room...

Страница 38: ...38 INSTALLATION GUIDE DEVIreg Room...

Страница 39: ...140R0040 AN461038960054en 010103 Produced by Danfoss 2023 11 INSTALLATION GUIDE DEVIreg Room Danfoss A S Nordborgvej 81 6430 Nordborg Denmark...

Страница 40: ...140F1161 DEVIreg Room Room thermostat 220 240V Load 16 A 3680 W 230V 50 60Hz 0T35 C IP21 MADE IN MALAYSIA Designed in Danmark 5 703466 250389 Danfoss Ltd 22 Wycombe End HP9 1NB GB 140R0040...

Отзывы: