The thermostat has a button to adjust the temperature
setting with a scale from -10°C to +50°C . An LED indicator
shows standby periods and heating periods (red light).
More information on this product can also be found at:
devireg devi com
.
1 1
Technical Specifications
Operation voltage
220 - 240V~, 50Hz
Standby power consumption
Max 0.25W
Relay:
Resistive load
Inductive load
Max 16A / 3680W @ 230V
cos φ= 0.3 max 1A
Sensing units
NTC 15 kOhm at 25 °C
Sensing values:
0 °C
25 °C
50 °C
42 kOhm
15 kOhm
6 kOhm
Hysteresis
0 ° to 6 °C
Ambient temperature
-10 °C to +45 °C
Lowering in economy periods
0 ° to 8 °C
Temperature range
-10 ° to +50 °C
Minimum temperature range
-10 °C to +5 °C
Cable specification max
1 x 4 mm2 or 2 x 2,5 mm2
Ball pressure temperature
75 °C