background image

Danfoss Solar Inverters A/S

 

Ulsnaes 1 

DK-6300 Graasten 

Denmark 

Tel: +45 7488 1300 

Fax: +45 7488 1301 

E-mail: [email protected] 

www.danfoss.com/solar 

Rev. date 2013-05-13  Lit. No. L00410618-03_02  

 

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products 

already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. 

All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

*139B0605*

139B0605

Содержание CLX Home

Страница 1: ...Danfoss CLX Home Installation Manual MAKING MODERN LIVING POSSIBLE SOLAR INVERTERS...

Страница 2: ...Remote Access 9 Delete Existing User from the Access Control List 10 Disable Remote Access 10 Navigating to Another CLX Monitored Plant 10 Plant Name 11 CO2 Emission 11 Revenue 11 Configuring Date an...

Страница 3: ...he scope of delivery Note Observe the manufacturer s instructions regarding the handling of power supply units espe cially switching units Observe the manufacturer s instructions regarding the handlin...

Страница 4: ...Area Legend 1 Power supply with circular connector 9 VDC 2 Ethernet port for LAN 3 4 RS 485 for connection to the inverter network 1 2 3 4 150AA021 10 Illustration 1 2 CLX Home Box LEDs LEDs LED 1 Gre...

Страница 5: ...delivery CLX Home Installation Manual Power supply RJ 45 termination plugs for terminating the RS 485 inverter network Ethernet cable standard network cable RJ 45 cat 5e for connecting the CLX Home b...

Страница 6: ...configuration it is important that the PC tablet or Smartphone with the Danfoss SolarApp installed are connected to the same local network as the CLX Home When the CLX Home is configured using a Smart...

Страница 7: ...rther details see the section Configuration First use of the Danfoss SolarApp 2 2 3 Browser Plugin Installation 1 Navigate to www clx danfoss com to download the browser plugin following the in struct...

Страница 8: ...ow the procedure and log in with an existing account or create a new one 3 1 Enter an email address and a password 3 2 Click on Create account 3 3 A verification email will come 3 4 Click on the link...

Страница 9: ...the main page of the current CLX box appears At the same time the CLX box is configured for re mote access by the current user Other users may be added as described in the section Set tings Granting R...

Страница 10: ...ting Remote Access Remote access of the CLX Home product is controlled via an access control list The user who configured the CLX Home box for initial use is always added automatically to the remote a...

Страница 11: ...A confirmation screen appears By pressing OK the user will be deleted from the ac cess control list Illustration 3 3 Access Control List 3 2 3 Disable Remote Access To disable remote access select Rem...

Страница 12: ...uired When used with out internet connection date and time must be set manually in order to ensure correct data logging 3 2 9 Language On the settings page the applications for current language can be...

Страница 13: ...ngs sections From the main page navigate to pages with more detailed information by clicking on the indi vidual circles and links Click on View production large circle to the left to see graphs with p...

Страница 14: ...ser navigation arrows will appear Illustration 4 2 Daily Production Monthly and yearly graphs are available by clicking on the buttons in the bottom area of the page By touching and holding the graph...

Страница 15: ...box logs detailed inverter data every 10 min The detailed inverter data is uploaded hourly to the CLX Portal when enabled The logging interval and the upload interval cannot be changed 4 2 3 Plant Sta...

Страница 16: ...de of operation of the inverter Latest event When an inverter event is present it is shown here Grid voltage for each phase V Present grid voltage measured by the inverter For each phase number of pha...

Страница 17: ...inimum cat5e shielded twisted pair cable is required Local visualisation operation App Enclosure 2 part fanless metal enclosure for rail mounting IP20 Weight 92 g net without accessories and external...

Страница 18: ...owing The CLX Home box has been turned on and connected correctly as described above with the LEDs flashing For initial configuration the computer tablet or Smartphone with the Danfoss Solar App insta...

Страница 19: ...catalogues brochures and other printed material Danfoss reserves the right to alter its products without notice This also applies to products already on order provided that such alterations can be ma...

Отзывы: