D
US
F
E
10 | AQ450440081306en-US0201
© Danfoss | Climate Solutions | 2023.07
Sun protection: If the compressor is set up outdoors, it has
to be protected from direct sunlight.
4
|
Compressor assembly
New compressors are factory-filled with inert gas. Leave this ser
-
vice charge in the compressor for as long as possible and prevent
the ingress of air. Check the compressor for transport damage
before starting any work.
ATTENTION
Attachments (e.g. pipe holders, additional units, fastening parts,
etc.) directly to the compressor are not permissible!
Setup on an even surface or frame with sufficient load-
bearing capacity.
Single compressor preferably on vibration damper.
Duplex and parallel circuits always rigid.
Provide adequate clearance for maintenance work.
Ensure adequate compressor ventilation.
Do not use in a corrosive, dusty, damp atmosphere or a
combustible environment.
4.2 Setting up
?
4.1 Storage and transport
Use transport eyelet.
Do not lift manually!
Use lifting gear!
Storage at (-30°C) - (+70°C), (-22 °F) - (158 °F), maximum permis-
sible relative humidity 10% - 95%, no condensation
Do not store in a corrosive, dusty, vaporous atmosphere or in a com-
bustible environment.