3.3 Orientation

The pump can be mounted/oriented in any 

horizontal direction. Vertically only with the shaft 

pointing upwards.

3.4  Protection from too high pressures

The pump should be protected against too high 

pressure by means of a pressure relief valve or a 

bypass/unloading valve placed on the pressure 

side.

The valve should be placed as close to the pump 

as possible. The opening characteristics of the 

valve must not result in peak pressures higher 

than 200 bar (2900 psi).

The valve outlet must not be connected 

directly to the pump suction line. It shall be 

connected directly to the tank.

3.5 Connections

APP 0.6-1.0

APP 1.5-2.5 and APP 3.0-3.5

P

T

C

P

T

C

Thread size

G 1/2 × 15

G 1/2 × 15

M6 Hexagon

NV 4

G 1/2 × 15

G 3/4 × 17

G 1/4, NV 6

14 deep

Max tighten 

torque

25 Nm

18 (lbf ft)

25 Nm

18 (lbf ft)

5 Nm

3.5 (lbf ft)

25 Nm

18 (lbf ft)

25 Nm

18 (lbf ft)

15 Nm

11 (lbf ft)

Recommended torque values refer to steel washers containing a rubber sealing element.

P Pressure

T Tank

C Bleeding

D   Parallel key 5 × 5 × 20, 

DIN 6885

Содержание APP 0.6

Страница 1: ...APP 0 6 1 0 APP 1 5 2 5 and APP 3 0 3 5 MAKING MODERN LIVING POSSIBLE Lenntech info lenntech com Tel 31 152 610 900 www lenntech com Fax 31 152 616 289 info lenntech com Tel 31 152 610 900 www lenntec...

Страница 2: ...ines for calculation of pressure losses 4 2 5 General comments on 4 3 Building up the pump unit 5 3 1 Mounting 5 3 2 Direction of rotation 5 3 3 Orientation 6 3 4 Protection from too high pressures 6...

Страница 3: ...mp 2 Place the inlet filter before the tank 3 Dimension the inlet line to obtain mini mum pressure loss large flow area minimum pipe length minimum number of bends connections fittings with small pres...

Страница 4: ...ng to below guidelines 2 5 General comments on Filtration A good ltration is vital to ensure a long and trouble free life of the pump When selecting a filter or strainer please note that filter materi...

Страница 5: ...all to separate the inlet from the outlet end of the tank Monitoring It is recommended to continuously monitor the following conditions Water level in the tank Filter contamination Pressure inlet and...

Страница 6: ...close to the pump as possible The opening characteristics of the valve must not result in peak pressures higher than 200 bar 2900 psi The valve outlet must not be connected directly to the pump suctio...

Страница 7: ...ssure gauge on the high pressure side 5 3 Dry running When running the pump must always be connected to the water supply in order to avoid damage if it should run dry In systems with water tank it is...

Страница 8: ...elf and there is thus no oil in the pump The pump requires no periodic replacements of seals and valve parts 6 2 Repair In case of irregular function in the pump please contact the Danfoss Sales Organ...

Отзывы: