manualshive.com logo in svg
background image

Instructions 

RI8NN35K

  ©  Danfoss  01/2010 

   AK-RC 101 / 103

In the event of any anomalies, the OPTYMA

TM

 Control 

warns  the  operator  by  displaying  alarm  codes  and 
sounding  the  warning  buzzer  inside  the  control 

Alarm codes

panel. If an alarm is tripped, the display will show one 
of the following messages:

Alarm code

Possible cause

Solution

E0

Cold room temperature sensor not working 
properly

•  Check that the cold room temperature  

 

  sensor is working properly.

•  If the problem persists, replace the sensor.

E1

Defrost sensor not working properly
(In this case defrosts will last time d3)

•  Check that the defrost sensor is working    

  properly.

•  If the problem persists, replace the sensor.

E2

Eeprom alarm
An EEPROM memory alarm has been detected
(All outputs except the alarm are deactivated)

•  Switch unit off and back on again.

E8

Man-in-cold-room alarm

•  Reset the alarm input inside the cold room

Ec

Compressor protection tripped (e.g. thermal 
protection or max. pressure switch)
(All outputs except the alarm– where 
applicable – are deactivated)

•  Check that compressor is working properly.
•  Check compressor absorption.
•  If the problem persists, contact the  

 

  technical assistance service.

Ed

Open door - alarm (Open door and tdo-time 
has expired)

Check door / door contact

Temperature 
shown on 
display is 
flashing 

Minimum or maximum temperature alarm.

The temperature inside the cold room has 
exceeded the min. or max. temperature 
alarm setting (see variables 

A1

 and 

A2

, user 

programming level)

•  Check that the compressor is working  

 

  properly.

•  Sensor not reading temperature correctly or 

  compressor start/stop control not working.

Содержание AK-RC 103

Страница 1: ...lslutninger Connections Anschl sse Raccordements Conexi n Anslutningar AK RC 101 AK RC 103 Se ogs manual RS8FD RS8FE See also manual Siehe auch Manual Voir aussi manuel Ver tambi n manual Se ocks manu...

Страница 2: ...V lvula solenoide Kriwan Kriwan Kriwan Kriwan Kriwan Pressure Pressostat HT LT Druckschalter Pressostat Control de pr sion Pump down Pump down Pump down Pump down Pump down Pump d mode Pump down mode...

Страница 3: ...or slukket 0 ventilatorerne k rer kontinuerligt 1 ventilatorerne k rer kun n r kompressoren arbejder 1 F4 Ventilatorpause under afrimning 0 ventilatorerne k rer under afrimning 1 ventilatorerne k rer...

Страница 4: ...registreret en EEPROM hukommelses alarm Alle udgange bortset fra alarmen deaktiveres Sluk enheden og t nd den igen E8 Person i k lerum alarm Nulstil alarmindgangen i k lerummet Ec Kompressorbeskyttel...

Страница 5: ...un continuously 1 fans only run when compressor is working 1 F4 Fan pause during defrost 0 fans run during defrost 1 fans do not run during defrost 1 dE Sensor presence 0 evaporator sensor present 1 n...

Страница 6: ...OM memory alarm has been detected All outputs except the alarm are deactivated Switch unit off and back on again E8 Man in cold room alarm Reset the alarm input inside the cold room Ec Compressor prot...

Страница 7: ...enn der Verdichter in Betrieb ist 1 F4 L fterstopp w hrend des Abtauens 0 L fter laufen beim Abtauen 1 L fter laufen beim Abtauen nicht 1 dE F hler 0 Abtauf hler vorhanden 1 kein Abtauf hler 0 d1 Abta...

Страница 8: ...gestellt alle Ausg nge au er dem Alarm sind deaktiviert Schalten Sie die Anlage ab und dann wieder ein E8 Alarm Person im K hlraum Setzen Sie den Alarmgeber im K hlraum zur ck Ec Verdichterschutz ausg...

Страница 9: ...marche continue 1 ventilateurs en marche uniquement si le compresseur fonctionne 1 F4 Arr t des ventilateurs pendant le d givrage 0 ventilateurs en marche pendant le d givrage 1 ventilateurs arr t s...

Страница 10: ...l alarme teindre puis rallumer l appareil E8 Alarme de pr sence d une personne dans la chambre R initialiser l entr e de l alarme ou le bouton coup de poing dans la chambre froide Ec Activation de la...

Страница 11: ...en funcionamiento continuo 1 ventiladores en marcha solo durante el funcionamiento del compresor 1 F4 Pausa de los ventiladores durante el desescarche 0 los ventiladores funcionan durante el desescar...

Страница 12: ...r n todas las salidas excepto las de alarma Apague el equipo y vuelva a encenderlo E8 Alarma de persona en la c mara frigor fica Restablezca la entrada de alarma en el interior de la c mara frigor fic...

Страница 13: ...1 normalt st ngd 0 F3 Fl ktstatus med kompressor OFF 0 fl ktarna k r kontinuerligt 1 fl ktarna k r bara n r kompressorn arbetar 1 F4 Fl ktstopp under avfrostning 0 fl ktarna k r under avfrostning 1 fl...

Страница 14: ...ckts Alla utg ngar f rutom larmrel et deaktiverade Sl av och p enheten E8 Man i kylrum larm Reset the alarm input inside the cold room Ec Kompressorskydd utl st termiskt skydd eller tryckbrytare Alla...

Страница 15: ...AK RC 101 103 Instructions RI8NN35K Danfoss 01 2010 15...

Страница 16: ...AK RC 101 103 The Product contains electrical components And may not be disposed together with domestic waste Equipment must be separate collected with Electrical and Elec tronic waste According to Lo...

Отзывы: