
AK-CC 550
Manual RS8EN502 © Danfoss 02-2010
31
Service
Temperature measured with S5 sensor
u09
1
1
1
1
1
1
1
1
1
1
Status on DI1 input. on/1=closed
u10
1
1
1
1
1
1
1
1
1
1
Actual defrost time (minutes)
u11
1
1
1
1
1
1
1
1
1
1
Temperature measured with S3 sensor
u12
1
1
1
1
1
1
1
1
1
1
Status on night operation (on or off) 1=on
u13
1
1
1
1
1
1
1
1
1
1
Temperature measured with S4 sensor
u16
1
1
1
1
1
1
1
1
1
1
Thermostat temperature
u17
1
1
1
1
1
1
1
1
1
1
Run time of thermostat (cooling time) in minutes
u18
1
1
1
1
1
1
1
1
1
1
Temperature of evaporator inlet temp
u19
1
1
1
1
1
1
1
1
1
1
Temperature of evaporator outlet temp.
u20
1
1
1
1
1
1
1
1
1
1
Superheat across evaporator
u21
1
1
1
1
1
1
1
1
1
1
Reference of superheat control
u22
1
1
1
1
1
1
1
1
1
1
Opening degree of AKV valve
**
u23
1
1
1
1
1
1
1
1
1
1
Evaporating pressure Po (relative)
u25
1
1
1
1
1
1
1
1
1
1
Evaporator temperature To (Calculated)
u26
1
1
1
1
1
1
1
1
1
1
Temperature measured with S6 sensor
(product temperature)
u36
1
1
1
1
1
1
1
1
1
Status on DI2 output. on/1=closed
u37
1
1
1
1
1
1
1
1
1
1
Air temperature . Weighted S3 and S4
u56
1
1
1
1
1
1
1
1
1
1
Measured temperature for alarm thermostat
u57
1
1
1
1
1
1
1
1
1
1
Status on relay for cooling
**
u58
1
1
1
1
Status on relay for fan
**
u59
1
1
1
1
1
1
1
1
1
1
Status on relay for defrost
**
u60
1
1
1
1
1
1
1
1
1
Status on relay for railheat
**
u61
1
1
1
1
1
1
1
Status on relay for alarm
**
u62
1
1
1
1
1
Status on relay for light
**
u63
1
1
1
1
1
1
1
1
Status on relay for valve in suction line
**
u64
1
Status on relay for compressor 2
**
u67
1
Temperature measured with S5B sensor
u75
1
Status on relay for hot
gas- / drain valve
**
u80
1
Status on relay for heating element in drip tray
**
u81
1
Status on relay for
night blinds
**
u82
1
Status on relay for defrost
B
**
u83
1
Status on relay for heat function
**
u84
1
Readout of the actual rail heat effect
u85
1
1
1
1
1
1
1
1: Thermostat 1 operating, 2: Thermostat 2 operating
u86
1
1
1
1
1
1
1
1
1
1
Status on high voltage input DI3
u87
1
1
1
1
1
1
1
1
1
1
Readout of thermostats actual cut in value
u90
1
1
1
1
1
1
1
1
1
1
Readout of thermostats actual cut out value
u91
1
1
1
1
1
1
1
1
1
1
Readout of status on the adaptive defrost
0: Off. Function is not activated
1: Error. A reset must be carried out using d22
2: Reset is activated. New tuning is in progress
3: Normal
4: Light build-up of ice
5: Medium build-up of ice
6: Heavy build-up of ice
U01
1
1
1
1
1
1
1
1
1
1
Continued
Code
1 2 3
4
5 6 7
8
9 10
Min.
Max.
Fac.
Actual
*) Can only be set when regulation is stopped (r12=0)
**) Can be controlled manually, but only when r12=-1
***) With access code 2 the access to these menus will be limited