Danfoss FT1370 Crimp Machine Operator’s Manual
AQ445452685725en-000101
© Danfoss FT1370 Crimp Machine Operator’s Manual | 2023.03. | 5
Setup and Assembly
1. Remove the pipe plug from the top cylinder port and install
the 2089-06-06S 90° adapter. Orient the adapter so that
it points to the rear of the crimp machine, away from the
operator.
2. Install the FC616-06 hose assembly to the cylinder adapter.
3. Install half of the FD35 quick-disconnect coupling to the end
of the FC616-06 hose assembly.
4. If using your own pump, make sure it has the requirements
listed in the Specifications section on the previous page.
5. Place the pump on the work surface to the right of the
crimper. Install the 2083-6-6S adapter and the other half of the
FD35 quick-disconnect coupling to the pump pressure port.
6. Connect the FD35 coupling to complete the hydraulic circuit.
7. Important: Remove excess air from the hydraulic system. This
can be accomplished by placing the pump at a higher level
than the cylinder and cycling the machine approximately five
times. If possible, tilt the crimp machine so the cylinder port is
at the “high point” of the machine.
8. Secure the machine frame to a stable work surface using lag
screws or other suitable fasteners.