8. Stop the prime mover, remove the pressure gauges, and return the system to its normal operating
configuration.
LS control adjustment: Adjustment screw, set screw, and gauge locations shown
M2
LS set screw
PC adjustment screw
L1
P109071
LS adjustment screw
PC set screw
Item
Description
Gauge
Port size
Wrench size
Torque
M2
1
Gauge port
300 bar [5000 psi]
9/16-18
1/4 inch internal hex
51 N•m [38 lbf•ft]
M14
4 mm internal hex
31 N•m [23 lbf•ft]
L1
Case drain port
10 bar [100 psi]
7/8-14
3/8 internal hex
95 N•m [70 lbf•ft]
X
LS/remote PC signal port
-
-
-
-
LS adj. screw
LS adjustment screw
-
-
6 mm internal hex
-
LS set screw
LS set screw
-
-
4 mm
9 N•m [7 lbf•ft]
PC adj. screw
PC adjustment screw
-
-
6 mm internal hex
-
PC set screw
PC set screw
-
-
4 mm
9 N•m [7 lbf•ft]
1
The M2 port is not available as a standard option.
Service Manual
Series 45 Frame K2 Open Circuit Axial Piston Pumps
Adjustments
©
Danfoss | April 2017
AX00000301en-US0101 | 25