General
Follow this procedure when starting-up a new Series 45 installation or when restarting an installation in
which the pump has been removed.
W
Warning
Unintended movement of the machine or mechanism may cause injury to the technician or bystanders.
To protect against unintended movement, secure the machine or disable/disconnect the mechanism
while servicing.
Prior to installing the pump, inspect for damage incurred during shipping. Make certain all system
components (reservoir, hoses, valves, fittings, heat exchanger, etc.) are clean prior to filling with fluid.
Start-up procedure
1. Connect the pump to the prime mover. Ensure that pump shaft is properly aligned with the shaft of
the prime mover.
C
Caution
Incorrect shaft alignment may result in damage to drive shaft, bearings, or seal which can cause
external oil leakage.
2. Fill the reservoir with recommended hydraulic fluid. Always filter fluid through a 10 micron filter
pouring into the reservoir. Never reuse hydraulic fluid.
3. Fill the main pump housing with clean hydraulic fluid. Pour filtered oil directly into the upper most
case drain port.
4. Fill the inlet line leading from the pump to the reservoir. Check the inlet line for properly tightened
fittings and be certain it is free of restrictions and air leaks.
5. To ensure the pump stays filled with oil, install the case drain line in the upper most case drain port.
6. Install a gauge at the system pressure gauge port to monitor system pressure during start up.
Follow recommendations in the vehicle/machine operator’s manual for prime mover start up
procedures.
7. While watching the pressure gauge installed at the system pressure gauge port, jog the prime mover
or run at the lowest possible speed until system pressure builds to normal levels (minimum 11 bar
[160 psi]). Once system pressure is established, increase to full operating speed. If system pressure is
not maintained, shut down the prime mover, determine cause, and take corrective action. Refer to
the
Troubleshooting
chapter.
8. Operate the hydraulic system for at least fifteen minutes under light load conditions.
9. Check and adjust control settings as necessary after installation. Refer to the
Adjustments
chapter.
10. Shut down the prime mover and remove the pressure gauge. Replace the plug at the system pressure
gauge port.
11. Check the fluid level in the reservoir; add clean filtered fluid if necessary.
The pump is now ready for operation.