background image

1.
2.
3.

4.

1.

2.

-

a.

-

b.

3.

-

a.

-

b.

4.
5.

1.
2.
3.

-

a.

-

b.

4.

-

a.

-

b.

5.

-

a.

-

b.

6.

1

RFI filter (optional)

2

M8 nut (13 mm)

3

AC fuse (optional)

4

R/S/T terminal label

5

Mains terminal block

6

Power terminal mounting plate

7

M8 nut (13 mm)

8

M5x11 screw (T20)

9

Motor terminal block

10

Mixing fan

2.3 Removing the Mains Terminal Block

To remove the mains terminal block, use the following steps.

Procedure

Disconnect the customer input power wiring.
Remove the R/S/T terminal label.
Remove 2 screws (T25) at the bottom of the mains terminal block.

If necessary, also remove 1 screw (T25) from the EMC shield near the lower end of the terminal block.

Slide the mains terminal block down to release it from the 2 metal clips on the mounting plate.

Discard the mains terminal block and terminal label.

2.4 Removing the Brake/Regen Terminal Block

If the drive includes either the brake option or regen/load share option, remove the terminal block using the following steps.

Procedure

Disconnect the wiring for the brake option or regen/load share option.

The brake/regen terminals are labeled R(+) and R(-).

Remove the R(+) busbar:

Unfasten 1 M4x8 thread-forming screw (T20) from the busbar at the terminal block.
Unfasten 1 screw (T40) at the upper end of the busbar.

Remove the R(-) busbar:

Unfasten 1 M4x8 thread-forming screw (T20) from the busbar at the terminal block.
Unfasten 1 M8 nut (13 mm) at the upper end of the busbar.

Remove 2 screws (T40) from the brake/regen terminal block.
Remove the brake/regen terminal block from the drive.

2.5 Removing the Motor Terminal Block

Procedure

Disconnect wiring to the motor.
Remove the U/V/W terminal label.
Remove the EMC shield:

Unfasten 2 screws (T25) from the base of the EMC shield.
Release the current sensor wiring from the cable clips on the EMC shield.

Remove the U motor busbar:

Remove 1 thread-forming screw (T25) from the middle of the busbar.
Unfasten 1 screw (T30) at the current sensor end of the busbar.

Remove the V motor busbar:

Remove 1 thread-forming screw (T25) from the middle of the busbar.
Unfasten 1 screw (T30) at the current sensor end of the busbar.

The V screw is shorter than the U and W screws.

Remove the W motor busbar:

 

AN275538690239en-000101 / 130R0721

6 | Danfoss A/S © 2022.11

Disassembly

300 A Current Sensor Kit for D1h/D3h/D5h/D6h Drives

Installation Guide

Содержание 176F6516

Страница 1: ...em Quantity EMC shield 1 M8 flange nut 3 M5x16 countersunk screw 3 Terminal plate 3 R S T terminal label 1 M10x30 machine screw 6 M10 hex nut 6 Mains terminal block 1 M5x12 screw 11 M5x16 thread formi...

Страница 2: ...IGBT output busbar 3 Hex busbar support bracket 1 M6 nut 3 M6x24 screw 3 Hex busbar 3 Nomex tube 3 300 A current sensor 3 M4x10 thread forming screw 6 Wire harness current sensor cables 1 M5x11 threa...

Страница 3: ...ts are off Failure to wait 20 minutes after power has been removed before performing service or repair work can result in death or serious injury Stop the motor Disconnect AC mains permanent magnet ty...

Страница 4: ...ions Remove 3 M8 nuts 13 mm at the top of the AC input busbars 1 per phase Remove 3 M8 nuts 13 mm at the bottom of the AC input busbars 1 per phase Remove 1 M8 nut 13 mm from the center busbar Remove...

Страница 5: ...ter to the side channels of the drive Remove the RFI filter and unplug the RFI cable from MK100 on the RFI filter card AC fuses and RFI filter Remove the AC fuses by removing 6 M8 nuts 13 mm 1 at each...

Страница 6: ...inals are labeled R and R Remove the R busbar Unfasten 1 M4x8 thread forming screw T20 from the busbar at the terminal block Unfasten 1 screw T40 at the upper end of the busbar Remove the R busbar Unf...

Страница 7: ...crewdriver under each of the mixing fan release tabs Lift to free the fan and housing from the power terminal mounting plate Unplug the mixing fan in line cable connector Remove 4 thread cutting screw...

Страница 8: ...s T20 from the corners of the mounting plate Remove 1 screw T25 from the top center of the mounting plate Remove the DC bus rails Remove 2 nuts 10 mm from the lower end of the DC bus rails 1 per bus r...

Страница 9: ...6 8 9 1 14 15 13 16 17 18 19 20 21 23 22 24 25 28 26 27 29 Illustration 4 Exploded View and Parts List of 300 A Current Sensor Kit AN275538690239en 000101 130R0721 9 Danfoss A S 2022 11 Reassembly 30...

Страница 10: ...screws T30 2 at the top of each IGBT output busbar Fasten 3 thread forming screws T25 1 at the top of each IGBT output busbar Install the new hex busbar support bracket Position the bracket over the 3...

Страница 11: ...the power terminal mounting plate by fastening 6 thread forming screws T20 2 per sensor Torque screws to 2 0 Nm 17 7 in lb Connect the wire harness by attaching 3 current sensor cables to the back of...

Страница 12: ...g screw T25 in the middle of the busbar Install the U motor busbar Slide the insulator sleeve over the U busbar Fasten 1 screw T30 in the current sensor end of the busbar Fasten 1 thread forming screw...

Страница 13: ...input busbars 1 per phase Position the 3 AC fuses in the drive Fasten 6 M8 nuts 13 mm 1 at each end of the 3 fuses Position the air baffle in the drive and fasten with 4 screws T25 RFI filter only Co...

Страница 14: ...oducts already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed All trademarks in this material are property of the re...