1.1.3 Items Supplied
Table 1.4
provides a list of items included in the 300 A and 500
A current sensor kits for D2h/D4h/D7h/D8h drives. Refer also
to
Illustration 1.4
.
Description
Quantity
R/S/T terminal label
1
M10x30 machine screw with captive washer
6
M10 nut
6
Mains input terminal block
1
M5x12 machine screw
12
U/V/W terminal label
1
Motor terminal block
1
Cable retaining clip
6
M10 nut with captive washer
4
Cable clamp adapter
2
Power terminal mounting plate (IP21/IP54)
1
Power terminal mounting plate (IP20/Chassis)
1
Mixing fan
1
Mixing fan housing
1
EMC shield
1
Plastic mounting button
3
Motor busbar (U)
1
Motor busbar (V)
1
Motor busbar (W)
1
Busbar insulator sleeve
1
M5x16 torx screw
3
M8x70 screw
3
Cylinder busbar
3
Nomex tube
3
300 A or 500 A current sensor
3
Wire harness (current sensor cables)
1
M4x10 thread-forming screw
6
M5 nut
2
Wire harness (current sensor cables)
1
Multiple wire guide, not shown
4
Wire routing clip, not shown
1
M5x11 thread-cutting screw, not shown
6
IGBT busbar (300 A kit only)
3
Table 1.4 Items Supplied in 300/500 A Current Sensor Kit
1.2 Safety
Information
Only qualified, Danfoss-authorized personnel are allowed to
install the parts described in these installation instructions.
Handling of the drive and its parts must be done in
accordance with the corresponding
operating guide
.
WARNING
ELECTRICAL SHOCK HAZARD
VLT
®
FC series drives contain dangerous voltages when
connected to mains voltage. Improper installation, and
installing or servicing with power connected, can cause
death, serious injury, or equipment failure.
To avoid death, serious injury, or equipment failure:
•
Only use qualified electricians for the installation.
•
Disconnect the drive from all power sources before
installation or service.
•
Treat the drive as live whenever the mains voltage
is connected.
•
Follow the guidelines in these instructions and local
electrical safety codes.
WARNING
DISCHARGE TIME
The drive contains DC-link capacitors, which can remain
charged even when the drive is not powered. High voltage
can be present even when the warning LED indicator lights
are off. Failure to wait the specified time after power has
been removed before performing service or repair work can
result in death or serious injury.
•
Stop the motor.
•
Disconnect AC mains and remote DC-link power
supplies, including battery back-ups, UPS, and DC-
link connections to other drives.
•
Disconnect or lock PM motor.
•
Wait for the capacitors to discharge fully. The
minimum waiting time is 20 minutes.
•
Before performing any service or repair work, use
an appropriate voltage measuring device to make
sure that the capacitors are fully discharged.
NOTICE
ELECTROSTATIC DISCHARGE
Follow proper ESD precautions to prevent damage to
sensitive components.
Installation Instructions
300 A/500 A Current Sensor Kit for D2h/D4h/D7h/D8h Drives
VLT
®
FC Series FC 102, FC 103, FC 202, FC 302
2
Danfoss A/S © 07/2018 All rights reserved.
MI70V202