manualshive.com logo in svg
background image

1

Sub D9 connector

3

Jack screw

2

Connector plate

4

Top of drive enclosure

Illustration 1.3 Connector Plate Installation

Installation Instructions

Top-entry Sub D9 Connector Kit for
Enclosure Sizes D and E with PROFIBUS Option
VLT

®

 FC Series FC 102, FC 103, FC 202, and FC 302

4

Danfoss A/S © 10/2017 All rights reserved.

MI38Q302

Содержание 176F1742

Страница 1: ... when connected to mains voltage Improper installation and installing or servicing with power connected can cause death serious injury or equipment failure To avoid death serious injury or equipment failure Only use qualified electricians for the installation Disconnect the drive from all power sources before installation or service Treat the drive as live whenever the mains voltage is connected F...

Страница 2: ... 7 1 Remove the front cover from the drive 2 Remove the local control panel LCP 3 Remove the LCP cradle by pulling the cradle outward See Illustration 1 1 4 Unfasten 2 M5 nuts 8 mm from the underside of the left cover plate and remove the plate from the drive enclosure Retain the 2 M5 nuts 1 Drive enclosure 3 LCP cradle 2 Left cover plate 4 LCP Illustration 1 1 Removal of LCP LCP Cradle and Left C...

Страница 3: ...sub D9 connector are seated firmly on the metal surface of the plate and not on the gasket 5d Place the assembled connector plate into the opening at the top of the drive enclosure See Illustration 1 3 1 Gasket 2 Connector plate 3 Opening for connector 4 Screw post Illustration 1 2 Gasket Installed on Connector Plate Installation Instructions Top entry Sub D9 Connector Kit for Enclosure Sizes D an...

Страница 4: ...ive enclosure Illustration 1 3 Connector Plate Installation Installation Instructions Top entry Sub D9 Connector Kit for Enclosure Sizes D and E with PROFIBUS Option VLT FC Series FC 102 FC 103 FC 202 and FC 302 4 Danfoss A S 10 2017 All rights reserved MI38Q302 ...

Страница 5: ...r easier connector installation remove the PROFIBUS module before attaching the Phoenix connector Then reinstall the PROFIBUS module 7 Plug the Phoenix connector into the PROFIBUS module See Illustration 1 5 1 Phoenix connector 2 PROFIBUS module Illustration 1 5 Phoenix Connector Installation 8 When the sub D9 connector is not in use 8a Place the rubber cover over the connector See Illustration 1 ...

Страница 6: ...e PROFIBUS module See Illustration 1 8 6 Fasten 1 M4 thread cutting screw T10 securing the strain relief in place 1 Bottom of left cover plate 2 M5 nut 3 Top of drive enclosure Illustration 1 7 Bottom View of Left Cover Plate from Inside Enclosure 1 M4 thread cutting screw 2 Strain relief Illustration 1 8 Strain Relief Installation Danfoss can accept no responsibility for possible errors in catalo...

Отзывы: