Programming event times in 5/2 day 

mode

You can programme your heating and hot water to come on 
and go of up to 3 times each day, to suit your requirements, 
with one set of programmes for weekdays and a different 
set of programmes for the weekend.  

Weekdays (MOTUWETHFR)



Press 

PROGRAMME

 until 1 

  

(Event 1) shows along the top of 

  

the display and 

MOTUWETHFR 

  

shows along the bottom.



Use the 

+ and -

 buttons to set the time you want your  

system to 

fi

 rst come on in the morning



Press 

PROGRAMME

 again to move to Event 2



Use the 

+ and -

 buttons to set the time you want your  

system to 

fi

 rst go off. 



Continue using the 

PROGRAMME 

and

 +/- buttons

  

in this way to set the ON/OFF times for events 3-6  
for weekdays.

Weekend (SASU) 

 Press 

PROGRAMME

 again until 

1 (Event 1) shows along the top 
of the display and 

SASU

 shows 

along the bottom of the display.



Use the 

PROGRAMME 

and

 +/- buttons

 to set the 

ON/OFF times for the weekend.

If at any time you wish to return to the factory preset 
programme, press 

SELECT / ADVANCE / + / -

 buttons 

together at the same time to reset the unit. 

NB. It is not possible to programme times out of sequence. 

Programming the unit - 5/2 day mode 

1

Содержание 102E5

Страница 1: ...Installation and User Guide Danfoss Heating 102E5 Electronic mini programmer for controlling hot water and heating Including Factory Replacement Units FRU...

Страница 2: ...programme 17 Temporary user overrides 18 Battery backup 19 Contact details 20 For a large print version of these instructions please call Marketing on 01234 364 621 Danfoss can accept no responsibili...

Страница 3: ...pply 230 15 Vac 50 Hz Switching action 1 x SPST Type 1B Switch rating 264 Vac 50 60Hz 3 1 A Timing Accuracy 1 min month Power Reserve Minimum 14 days Enclosure Rating IP30 Max Ambient Temperature 45 C...

Страница 4: ...or plaster box as required Ensure that the screw heads do not protrude beyond the vertical centre rib of the wallplate or this will prevent the module correctly locating onto the wallplate 4 Surface...

Страница 5: ...5 2 day To convert to 5 2 day mode remove the small two way connector from the pins towards the left of the recess on the rear of the module then press the SELECT ADVANCE buttons all at the same time...

Страница 6: ...n the display lines up with the word ON and check that the water circuit only operates 12 When the circuit check has been completed replace the wiring cover and tighten the fixing screw Cut any cable...

Страница 7: ...ALL N PUMP TERMINALS BOILER TERMINALS 102E5 TERMINALS Typical Gravity DHW with Pumped Heating Typical domestic gas or oil fired central heating system with gravity hot water and pumped heating If a ro...

Страница 8: ...nfoss Randall 102E5 HEATSHARE pack which also includes the TW room thermostat AT cylinder thermostat HS3 mid position valve and a WB12 wiring box 1 2 3 5 6 L N L N MAINS SUPPLY FUSED 3 AMP ROOM STAT L...

Страница 9: ...PUMP TERMINALS L N MAINS SUPPLY FUSED 3 AMP LINK COM CALL N N COM CYL STAT CALL N SAT ROOM STAT HEATING VALVE D H W VALVE The above control system is available as the Danfoss Randall 102E5 HEATPLAN pa...

Страница 10: ...rminated 1 2 3 5 N 6 L A B C RANDALL 102 102E 102E7 1 2 3 5 6 RANDALL 3020P 3060 4 2 1 7 6 3 5 RANDALL MKII R6 4 5 3 1 2 6 7 HORSTMANN CORAL 423 424 Boiler 8 Air Stat 8 2 3 1 4 7 5 6 HORSTMANN DIAMOND...

Страница 11: ...THS IND CENTROLLER 10 3 2 N L 1 4 SMITHS IND CENTROLLER 70 5 4 1 2 3 6 SWITCHMASTER 320 350 3 1 N 4 L 2 SWITCHMASTER 600 3 1 N L 2 4 VENNER VENOTROL V S F N A M L L1 T P 0 VENNER VENOTROL 80 Air Stat...

Страница 12: ...ng and hot water on and off at times that suit you The 102E5 can provide 3 ON periods and 3 OFF periods each day and can offer either 24 hour control same programme for each day of the week or 5 2 day...

Страница 13: ...s PROGRAMME once Use and buttons to set the correct time press and hold to change in 10 min increments When time is correct press PROGRAMME again In 24 hour mode this will take you straight to program...

Страница 14: ...10 30pm 10 30pm NB 2nd ON and 2nd OFF are set to the same time These 2 times are ignored by the programme therefore the heating will just come on once in the morning and once in the evening If you wan...

Страница 15: ...ons to set the time you want your system to first come on in the morning Press PROGRAMME again to move to the next step Event 2 Use the and buttons to set the time you want your system to first go off...

Страница 16: ...ing Press PROGRAMME again to move to Event 2 Use the and buttons to set the time you want your system to first go off Continue using the PROGRAMME and buttons in this way to set the ON OFF times for e...

Страница 17: ...hot water heating will remain on constantly OFF the hot water heating will not come on AUTO the hot water heating will come on and go off according to the programmed times ALLDAY the unit will come on...

Страница 18: ...t will come on for an hour If it is already on it will add an extra hour so the system stays on for an extra hour To cancel the override press 1HOUR again red light will go off ADVANCE does not work w...

Страница 19: ...ays After 15 days without mains power the unit will switch off and two dots will show in the display However all your programmed on off times will be remembered When the mains power is restored the un...

Страница 20: ...till having problems Call your local heating engineer Name Tel Visit our website www heating danfoss co uk Email our technical department ukheating technical danfoss com Call our technical department...

Отзывы: