January 2003

CI.46.C4.62

1

8238-15

The fan output can supply a continous current
of 0.5A

avg

. A higher current draw is allowed for 2

seconds during start.
LED (optional, Fig. 1)
A 10mA light emitting diode (LED) (6) can be
connected between  the terminals + and D.
In case the electronic unit records an operational
error, the diode will flash a number of times. The
number of flashes depends on what kind of
operational error was recorded. Each flash will
last ¼ second. After the actual number of flashes
there will be a delay  with no flashes, so that the
sequence for each error recording is repeated
every 4 seconds.

-

+

+

-

+

-

+
F

D
C
P

T

3

5

4

7

2

8

6

9

1

8380

Visit our Homepage: www.danfoss.com/compressors

CI.46.C4.02 12-02

The electronic unit is a dual voltage device. This
means that the same unit can be used in both
12V and 24V power supply systems. Maximum
voltage is 17V for a 12V system and 31.5V for a
24V power supply system. Max. ambient tem-
perature is 55°C. The  electronic unit has a built-
in thermal protection which is actuated and stops
compressor operation if the electronic unit tem-
perature gets too high.

Installation (Fig. 1)
Connect the terminal plug from the electronic unit
to the compressor terminal. Mount the electronic
unit on the compressor by snapping the cover
over the screw head (1).

Power supply (Fig. 1)
The electronic unit must always be connected
directly to the battery poles (2). Connect the plus
to + and the minus to -, otherwise the electronic
unit will not work. The electronic unit is protected
against reverse battery connection.
For protection of the installation, a fuse (3) must
be mounted in the cable as close to the battery
as possible. 15A fuse for 12V and 7.5A fuse for
24V circuits are recommended.
If a main switch (4) is used, it should be rated to
a current of min. 20A.
The wire dimensions in Fig. 2 must be observed.
Avoid extra junctions in the power supply system
to prevent voltage drop from affecting the battery
protection setting.

Battery protection (Fig. 1)
The compressor is stopped and re-started again

according to the decided voltage limits measured
on the  and terminals of the electronic unit.
The standard settings for 12V and 24V power
supply systems appear from Fig. 3.
Other settings (Fig. 4) are optional if a connection
which includes a resistor (9) is established
between terminals C and P.
In solar applications without a battery a 220 k

resistor is recommended. In AEO (Adaptive Ener-
gy Optimizing) speed mode  the BD compressor
will always adapt its speed to the actual cooling
demand within a random operation voltage of
9.6 to 31.5V.

Thermostat (Fig. 1)
The thermostat (7) is connected between the
terminals C and T. Without any resistor in the
control circuit, the compressor with electronic unit
101N0210 or 101N0220 will run with a fixed speed
of  2,000 rpm when the thermostat is switched
on.

 With the thermostat directly connected to

terminal C the electronic unit 101N0300 will adjust
its speed to the actual cooling demand.
Other fixed compressor speeds in the range
between 2,000 and 3,500 rpm can be obtained
when a resistor (8) is installed to adjust the
current (mA) of the control circuit. Resistor
values for various motor speeds appear from
Fig. 5.

Fan (optional, Fig. 1)
A fan (5) can be connected between  the
terminals + and F. Connect the plus to + and the
minus to F. Since the output voltage  between the
terminals  + and is always regulated to 12V,
a 12V fan must be used for both 12V and 24V
power supply systems.

Fig. 1

Optional battery
protection settings

24V max.

Voltage

31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5

24V cut-in

V

22.7
22.9
23.2
23.4
23.7
23.9
24.2
24.5
24.7
25.0
25.2
25.5
25.7
26.0

24V cut-out

V

21.3
21.5
21.8
22.0
22.3
22.5
22.8
23.0
23.3
23.6
23.8
24.1
24.3
24.6

12V max.

Voltage

17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0

12V cut-in

V

10.9
11.0
11.1
11.3
11.4
11.5
11.7
11.8
11.9
12.0
12.2
12.3
12.4
12.5
10.9

12V cut-out

V

9.6
9.7
9.9

10.0
10.1
10.2
10.4
10.5
10.6
10.8
10.9
11.0
11.1
11.3

9.6

Resistor

(9) k

0

1.6
2.4
3.6
4.7
6.2
8.2

11
14
18
24
33
47
82

220

  

Fig. 4

ENGLISH

Max length*

m

24V

 operation

5
8

12
20

Cross

section

mm

2

2.5

4
6

10

Max length*

m

12V

 operation

2.5

4
6

10

Wire dimensions

Fig. 2

*Length between battery

and electronic unit

Fig. 3

24V cut-out

V

22.8

12V cut-in

V

11.7

24V cut - in

V

24.2

12V cut-out

V

10.4

Standard battery protection settings

Number

of

flashes

Error type

Thermal cut-out of electronic unit

(If the refrigeration system has been too
heavily loaded, or if the ambient temperature
is high, the electronic unit
will run too hot).

5

Minimum motor speed error

(If the refrigeration system is too heavily
loaded, the motor cannot maintain minimum
speed 1,850 rpm).

4

Motor start error

3

(The rotor is blocked or the differential
pressure in the refrigeration system is too
high (>5 bar)).

Fan over-current cut-out

2

(The fan loads the electronic unit with more
than 1A

peak

).

1

Battery protection cut-out

(The voltage is outside the cut-out setting).

Instructions

Electronic Unit for BD35/50F Compressors,

101N0210, 101N0220 and 101N0300, 12-24V

Fig. 5

Motor

speed

rpm

2,000
2,500
3,000
3,500

AEO

2,000
2,500
3,000
3,500

Resistor

(8)

0

277
692

1523

0

173
450
865

1696

Contr.circ.

current

mA

5
4
3
2
6
5
4
3
2

Compressor speed

Electronic

unit

101N0210

101N0220

101N0300

with AEO

Содержание 101N0210

Страница 1: ...Electronic Control Unit ECU on the compressor Then unplug the ECU from the compressor and check the resistance on the compressor pins It should be about 2 5 ohms between all three pairs 1 2 2 3 and 1...

Страница 2: ...hermostat Fig 1 The thermostat 7 is connected between the terminals C and T Without any resistor in the control circuit the compressor with electronic unit 101N0210 or 101N0220 will run with a fixed s...

Страница 3: ...ereich von 9 6 bis 31 5V Thermostat Abb 1 Der Thermostat 7 wird an die Anschlu klem men C und T angeschlossen Ohne einen Wider stand im Steuerkreis l uft der Verdichter mit elek tronischer Steuerungse...

Страница 4: ...tance de 220 k est recommand e En mode de vitesse AEO Adaptation Energie Opti mis e le compresseur BD modulera toujours sa vitesse de rotation en fonction de la demande de froid sur une plage de tensi...

Страница 5: ...ad a la demanda de refrigeraci n actual dentro de un rango de tensi n de funcionamiento de 9 6 a 31 5 V Termostato fig 1 El termostato 7 est conectado entre los termi nales C y T Sin resistencia en el...

Страница 6: ...Nella modalit AEO ottimi zzazione energetica mediante controllo adatta tivo il compressore BD adatter sempre la pro pria velocit alla reale richiesta di resa frigorifera entro una tensione d esercizio...

Страница 7: ...ruikt wordt zonder batterij is een weerstand van 220 k aanbevolen In AEO Adaptive Energy Optimizing modus past de compressor zijn snelheid altijd aan in functie van de vraag naar koeling en dit binnen...

Страница 8: ...lk rlig driftssp nding fra 9 6 til 31 5V Termostat fig 1 Termostaten 7 tilsluttes mellem klemme C og T Uden modstand i kontrolkredsl bet arbejder kompressoren med den elektroniske enhed 101N0210 eller...

Страница 9: ...varvtalet till aktuellt kylbehov inom sp nningsomr det 9 6 till 31 5 volt Termostat fig 1 Termostaten 7 r ansluten mellan anslutning arna C och T Utan motst nd i kontrollkretsen kommer kompressorn me...

Страница 10: ...la 101N0210 tai 101N0220 py rii vakionopeudella 2000 kierr min termostaatin ollessa kytkettyn p lle Kun termostaatti on suoraan kytketty C liitimeen s hk osa 101N0300 s t nopeuden todellisen kylm tarp...

Отзывы: