212-0024-6SS
9
July 30th, 2019
Programming the PDU-6SS
NOTE: If no action is taken within 20 seconds during setup, the PDU will return to Standby Mode.
Low Voltage Shutdown Setup
The PDU-16SS’ factory default LOW VOLTAGE SHUTDOWN value is set to 11.5 VDC for both Group 1 and
Group 2 outputs. This value can be adjusted by the user for each of the two output groups separately by fol-
lowing these steps:
Tap the VOLTAGE SETUP/RESET button. The VL GRP1 LED will turn ON and the display will show the
current voltage set for GROUP 1 outputs. Tap the UP or DOWN buttons to enter the new voltage.
Tap the VOLTAGE SETUP/RESET button. The VL GRP2 LED will turn ON and the display will show the
current voltage set for GROUP 2 outputs. Tap the UP or DOWN buttons to enter the new voltage.
Tap the VOLTAGE SETUP/RESET button again to save the new values.
Note: - When the vehicle battery voltage drops below the pre-set voltage the outputs will turn off. This
is the same for both groups.
- The
minimum shutdown voltage cannot be set below 11.5VDC unless the vehicle is being fitted
with a second battery.
Timed Shutdown Setup
The PDU-6SS factory default shutdown times are set to:
2 minutes for GROUP 1 outputs
2 hours for GROUP 2 outputs
This value can be adjusted by the user by following these steps:
Tap the TIME SETUP/TEST button. The TIME GRP1 LED will turn ON and the display will show the cur-
rent shutdown time set for GROUP 1 outputs. Tap the UP or DOWN buttons to enter the new time.
Tap the TIME SETUP/TEST button. The TIME GRP2 LED will turn ON and the display will show the cur-
rent shutdown time set for GROUP 2 outputs. Tap the UP or DOWN buttons to enter the new time.
Tap the TIMER SETUP/TEST button again to save the new values.
Note:
When the vehicle IGNITION switch is turned on, the countdown will be stopped.