background image

 

212-0024-6SS 

July 30th, 2019

 

Automotive Power Distribution Unit  

User Manual 

Model: 

PDU-6SS 

Table of Contents 

Product Overview………………………………………………………………………………………………………………………………………………………………………..……2 

Introduction/Features/Technical Specifications……….……………………………………………………………………………………………………………………….3 

Warnings…………………………………………………………………………………………………………………………………………………………………………………………..4 

Installation………………………………………………………………………………………………………………………………………………………………………………………..5 

Wiring Diagram………………………………………………………………………………………………………………………………………………………………………………...6 

Wire Gauge Size Tables……………………………………………………………………………………………………………………………………………………………………..7 

Modes of Operation………………………………………………………………………………………………………………………………………………………………………….8 

Programming Low Voltage Shutdown and Timed Shutdown……………………………………………………………………………………………………………..9 

Package Contents……………………………………………………………………………………………………………………………………………………………………………10 

Warranty and Product Return Policy……………………………………………………………………………………………………………………………………………...12 

Содержание PDU-6SS

Страница 1: ...SS Table of Contents Product Overview 2 Introduction Features Technical Specifications 3 Warnings 4 Installation 5 Wiring Diagram 6 Wire Gauge Size Tables 7 Modes of Operation 8 Programming Low Voltage Shutdown and Timed Shutdown 9 Package Contents 10 Warranty and Product Return Policy 12 ...

Страница 2: ...212 0024 6SS 2 July 30th 2019 Product Overview Figure 1 PDU 6SS ...

Страница 3: ... Shutdown 2 minutes TO 30 hours Vehicle Battery Voltage Monitoring Each output has an LED fuse status indicator ZERO Current consumption in Standby Mode Timed Shutdown Mode Test Mode all outputs ON for 20 seconds Reset Mode resets all outputs to zero 6 Outputs 1 battery and 5 timed Technical Specifications Voltage Range 11 18 VDC Maximum Current Load 15A per output fused at 20A 25A per heavy duty ...

Страница 4: ...hould be properly trained in the operation of this device to ensure both operator and public safety 9 Any device used inside a vehicle may cause severe personal injury if not properly mounted and secured Objects used in the vehicle may become airborne during a collision or other sudden chang es in vehicle speed or direction such as braking acceleration or turns 10 Be sure to mount unit through the...

Страница 5: ...ound Using appropriate size wire connect to the negative battery terminal or a suitable chassis ground Ignition Sense Connect this terminal to the vehicle ignition switch using 18 gauge wire Battery Sense Connect this terminal directly to the positive of the battery using a 18 gauge wire fused with a 5A fuse This connection must be made in order for the PDU 6SS to work Ground Sense Connect this te...

Страница 6: ...212 0024 6SS 6 July 30th 2019 Figure 2 Wiring Wiring Diagram ...

Страница 7: ...ngth 3 drop 5 ft 5 10 ft 10 15 ft 15 20 ft 25 30 ft 25 10 6 6 4 2 50 6 4 2 2 0 75 6 2 1 0 3 0 100 4 2 0 2 0 4 0 Table 2 Recommended Circuit Load Wire Size Max Total Load Current Amps Wire Size AWG vs Wire Length 3 drop 1 5 ft 5 10 ft 10 15 ft 15 20 ft 25 30 ft 5 18 18 18 16 14 10 18 16 14 14 12 15 18 14 12 12 10 20 16 14 12 10 8 ...

Страница 8: ...voltage reaches a pre set value This setting is the same for both groups Timed Shutdown Mode The PDU allows the user to set the time remaining after the ignition switch is turned off This setting is the same for both groups The 7 segment display will cycle through and indicate the time remaining for each output group Test Mode Pressing the TIME SETUP TEST button for at least 2 seconds will start a...

Страница 9: ...ET button again to save the new values Note When the vehicle battery voltage drops below the pre set voltage the outputs will turn off This is the same for both groups The minimum shutdown voltage cannot be set below 11 5VDC unless the vehicle is being fitted with a second battery Timed Shutdown Setup The PDU 6SS factory default shutdown times are set to 2 minutes for GROUP 1 outputs 2 hours for G...

Страница 10: ... 16 out display dual programmable timer and voltage 1 212 0024 6SS Manual PDU 6SS unit 1 Designator sheet for PDU 6SS to record all setup installation data 4 196 0070 Lug LD 6 AWG stud 1 4 16 205 0052 Spade 8 16 14 Ga Package Contents NOTE MINI and MAXI fuses are available for purchase ...

Страница 11: ...212 0024 6SS 11 July 30th 2019 NOTES ...

Страница 12: ...or removal or installation Lamps flash tubes batteries or other items considered consumables are not covered under warranty This warranty is in lieu of all other express warranties D R Electronics makes no warranties ex pressed or implied other than the express warranties contained herein WARRANTY PRODUCT RETURN POLICY In order to provide you with faster service product returns for repair or repla...