Explanation for function mapping
If you want to activate a function enter the value to the corresponding output according to the following
table. In case you want to activate several different functions by one and the same output you must add up
their specific values.
Output's values:
RG
ABL
AUX4
AUX3
AUX2
AUX1
LR
LV
Value
128
64
32
16
8
4
2
1
RG = Shunting gear ABL = dimmed headlights
Example:
F4 should activate the shunting gear and switch on the outputs LV and LR:
LV=1, LR=2, RG=128: so you must enter the value 131 in CV38 | par066.
Notice:
AUX4, AUX3 and AUX2 are not available in the decoder DHP160.
Timer function
(CV 117 - 120, par076 - 079)
Value = 0
The timer is switched off (continuous operation)
Value = 1…250
The timer is activated, the correspondent output will be disconnected after the set time
of: entered value x 0,1 sec.