26
041
Operating system
Occurs during the programming
automatically:
Bit
System
Value
0
SX1
1
1
DCC
2
2
SX2
4
1, 2, 4
2
051
Characteristic diagram
Response curve
0 = linear
7 = logarithmic
See supplement 2
0 – 7
5
052
Regulation variant
0 = user defined by par056 ff.
1 = Hard
2 = Soft
3 = Very Soft
0 – 3
2
053
Impulse width
0 = 1 ms
1 = 2 ms
2 = 4 ms
3 = 8 ms
0 – 3
1
054
Motor frequency
0 = 32 kHz,
2 = low frequency
0, 2
0
056
Motor proportional controller
Only if activated by par052 = 0
0 – 7
3
057
Motor integral controller
Only if activated by par052 = 0
0 – 3
3
058
Motor measurement period
Only if activated by par052 = 0
0 – 3
1
059
Motor impulse width
Only if activated by par052 = 0
0 – 7
3
061
Function mapping F0(f)
See supplement 1
0 – 255
1
062
Function mapping F0(r)
See supplement 1
0 – 255
2