background image

 

5.2. I/O panel

For systems not using Dante audio, inputs and input links can be

directly connected to the I/O panel

5.2.1. INPUT section

The INPUT section represents the input connectors of the first

amplifier while the other amplifiers are linked within the rack. The

INPUT section allows both analog and digital audio signals to be

fed to the amplifier.

5.2.2. INPUT LINK section

The INPUT LINK section represents the link output connectors of the

last amplifier and allows the linking of further system racks using

the enclosed rack link cable (Z5333 Rack link).

5.2.3. REMOTE section

The REMOTE section allows the daisy chaining of rack assemblies

within a remote network using the enclosed rack link cable (Z5333

Rack Link).

For detailed specifications, please refer to the following sections:

Þ

  Ethernet network

Þ

  CAN-Bus network

I/O panel, rack link example:
2ch Analog audio and Ethernet/OCA
DS10 mode: Red VLAN

 

Ethernet network
For remote purposes via Ethernet/OCA, it is strongly

recommended to use the prewired configuration in combination

with the DS10 when linking entire rack assemblies, as shown in the

graphic opposite.

It is recommended to link a maximum of up to 6 rack assemblies in

this way.

Do not link/daisy chain entire rack assemblies using the ETH 1/

ETH 2 connector sockets of the I/O panel.

 

d&b Z5576.000 Manual 1.1 en

14

Содержание Z5576.000

Страница 1: ...D Z5576 000 Manual 1 1 en...

Страница 2: ...d b website for the latest version of this manual When reselling this product hand over this manual to the new owner If you supply d b products please draw the attention of your customers to this man...

Страница 3: ...8 3 2 1 MAINS IN 8 3 3 Front panel 9 3 3 1 MAINS 9 3 3 2 AUXILIARY MAINS OUTPUTS 9 4 Z5578 LS connector panel 6 x NL8 2 x LKA25 10 4 1 Intended use 10 4 2 ETH POE INCLINOMETER 10 4 3 4 CH OUTPUTS 11 4...

Страница 4: ...peaker connector panel Z5578 In addition the Z5578 loudspeaker connector panel incorporates a POE Power Over Ethernet enabled etherCON RJ 45 connector for the direct connection of an inclinometer Also...

Страница 5: ...19 frame Including 2 1 Z5577 000 Mains power distributor 32 A CEE 3 1 Z5578 000 LS Connector panel 2 x LKA 25 6 x NL8 4 6 Z2710 D80 Amplifier 5 1 Z5338 I O Panel 6 1 Z4010 DS10 Audio Network Bridge 7...

Страница 6: ...rack to ensure adequate cooling airflow Make sure both the front and rear doors are opened and pushed into their park position to provide sufficient cooling Do not stack Z5576 000 Touring rack assembl...

Страница 7: ...rack assembly that produces an opposing airflow observe the following restrictions Do not stack D12 Touring racks or any other rack assemblies with opposing airflow on top of the Z5576 000 Touring rac...

Страница 8: ...do not use the unit and replace it before further use Do not connect or disconnect the CEE mains connector under load or live Please ensure the mains connector is accessible at any time to disconnect...

Страница 9: ...e available Three sockets are mounted on the front and four sockets on the rear panel Two of the rear sockets are used to provide mains supply for the POE injector device and the DS10 The remaining so...

Страница 10: ...o feed an inclinometer which is integrated in the flying frame for vertical aiming of the entire array E8106 POE Injector device In connection with the ETH POE INCLINOMETER socket a corresponding IEEE...

Страница 11: ...eg 4 4 12 CH OUTPUT Two 12 CH OUTPUT multipin connectors LKA25 are provided to allow efficient system wiring using the d b MC24 multicore system Z5328 xxx MC24 LKA25 F M Multicore Z5325 000 Break out...

Страница 12: ...NL8 Amplifier A 1 AMP 1 A 1 AMP 4 B 1 B 1 C 2 C 2 D 2 D 2 E 3 E 3 F 3 F 3 G 4 G 4 H 4 H 4 I 1 AMP 2 I 1 AMP 5 J 1 J 1 K 2 K 2 L 2 L 2 M 3 M 3 N 3 N 3 O 4 O 4 P 4 P 4 Q 1 AMP 3 Q 1 AMP 6 R 1 R 1 T 2 T...

Страница 13: ...o provide access to the amplifiers The DS10 in combination with the I O panel allows various configurations Two recommended configurations are detailed below Note For detailed information on how to co...

Страница 14: ...REMOTE section The REMOTE section allows the daisy chaining of rack assemblies within a remote network using the enclosed rack link cable Z5333 Rack Link For detailed specifications please refer to th...

Страница 15: ...ntrol via the d b Remote network CAN Bus is given in the technical information TI 312 d b code D5312 EN which can be downloaded from the d b website at www dbaudio com 5 3 Z5333 Rack Link The rack lin...

Страница 16: ...Mains power connection and internal mains supply distribution 6 Rack wiring diagrams d b Z5576 000 Manual 1 1 en 16...

Страница 17: ...Internal 4 CHANNEL OUTPUT wiring d b Z5576 000 Manual 1 1 en 17...

Страница 18: ...Internal audio INPUT and LINK wiring d b Z5576 000 Manual 1 1 en 18...

Страница 19: ...Internal Ethernet wiring and POE injection d b Z5576 000 Manual 1 1 en 19...

Страница 20: ...Internal CAN Bus wiring d b Z5576 000 Manual 1 1 en 20...

Страница 21: ......

Страница 22: ...D2029 EN 01 04 2018 d b audiotechnik GmbH www dbaudio com...

Отзывы: