background image

 

2.5  Technical specifications

System data

Frequency response (–5 dB standard)

60 Hz - 18 kHz

Frequency response (–5 dB CUT mode)

90 Hz - 18 kHz

Max. sound pressure (1 m, free field)
XSL8 with D40/D80

141 dB

XSL12 with D40/D80

140 dB

(SPLmax: Broadband signal IEC 60268)

Loudspeaker data

Nominal impedance front LF

8 ohms

Nominal impedance side LF/MF/HF

8 ohms

Power handling capacity front LF (RMS/peak 10 ms)

400/1200 W

Power handling capacity side LF/MF/HF (RMS/peak 10 ms)

300/850 W

Nominal horizontal dispersion angle
XSL8

80°

XSL12

120°

Splay angle setting

0 ... 14° (1° increment)

Components

2 x 8" front LF driver

2 x 6.5" side LF driver

1 x 6.5" MF driver

2 x 1" exit compression driver with 2" coil

Passive crossover network

Connections

NLT4 F/M

Pin assignment

1+: Front LF+/1–: Front LF–

2+: Side LF/MF/HF+/2–: Side LF/MF/HF–

Weight

39 kg (86 lb)

XSL8: Frequency response*, Standard and CUT modes
*
single cabinet within array

XSL12: Frequency response*, Standard and CUT modes
*
single cabinet within array

 

d&b XSL8/XSL12 Manual 1.2 en

10

Содержание XSL8

Страница 1: ...SLXSL8 XSL12 Manual 1 2 en...

Страница 2: ...larly check the d b website for the latest version of this document When reselling this product hand over this document to the new owner If you supply d b products please draw the attention of your cu...

Страница 3: ...nded use 6 2 2 Connections 7 2 3 Operation 7 2 3 1 Controller settings 8 2 4 Dispersion characteristics 9 2 5 Technical specifications 10 3 Manufacturer s declarations 12 3 1 Conformity of loudspeaker...

Страница 4: ...maximum load capacity of the accessories as detailed in our specific Mounting instructions or in our Rigging manuals Ensure that all additional hardware fixings and fasteners used for deployment are...

Страница 5: ...topics In addition ArrayCalc will provide you with typical array configurations within the permitted load limits and will help you get familiar with the mechanical load conditions and limitations d b...

Страница 6: ...ounted to a dedicated wave shaping device The cylindrical wave segments of each cabinet couple without gaps and sum up coherently Splay angles between adjacent cabinets can be set in the range from 0...

Страница 7: ...applicable loudspeakers LoadMatch is therefore independent of the connector type used 2 3 Operation Amplifier output mode s 2 Way Active Application Setup Cabinets per pair of amplifier channels XSL8...

Страница 8: ...gnal Coupling function The Coupling function compensates for coupling effects between the cabinets by reducing the low and low mid frequency level The SL Series setups provide a two stage filter Low M...

Страница 9: ...angle over frequency plotted using lines of equal sound pressure isobars at 6 dB and 12 dB The nominal horizontal dispersion of 80 120 is maintained over the entire operating bandwidth XSL12 isobar di...

Страница 10: ...1200 W Power handling capacity side LF MF HF RMS peak 10 ms 300 850 W Nominal horizontal dispersion angle XSL8 80 XSL12 120 Splay angle setting 0 14 1 increment Components 2 x 8 front LF driver 2 x 6...

Страница 11: ...XSL8 XSL12 cabinet dimensions in mm inch d b XSL8 XSL12 Manual 1 2 en 11...

Страница 12: ...uding all applicable amendments Detailed and applicable declarations are available on request and can be ordered from d b or downloaded from the d b website at www dbaudio com 3 2 WEEE Declaration Dis...

Страница 13: ......

Страница 14: ...D2752 EN 01 02 2022 d b audiotechnik GmbH Co KG www dbaudio com...

Отзывы: