background image

 

HFA mode
In HFA mode (High Frequency Attenuation), the HF response of the

system is rolled off. HFA provides a natural, balanced frequency

response when a cabinet is placed close to listeners in near field or

delay use.

High Frequency Attenuation begins gradually at 1 kHz, dropping

by approximately 3 dB at 10 kHz. This roll off mimics the decline

in frequency response experienced when listening to a system from

a distance in a typically reverberant room or auditorium.

CPL function
The CPL (Coupling) function compensates for coupling effects

between the cabinet and close boundary surfaces. CPL begins

gradually around 1 kHz, with the maximum attenuation below

400 Hz. To achieve a balanced frequency response, the CPL

function can be set to dB attenuation values between 0 and –9.

Positive CPL values create an adjustable low frequency boost (0 to

+5 dB) at around 65 Hz and can be set when the system is used in

full range mode without subwoofers.

-5

0

5

10

-10

-15

-20

-25

-30

20

100

1k

10k

20k

Frequency response correction in HFA mode

Frequency response correction of the CPL function

 

d&b V7P/V10P Manual 1.3 en

7

Содержание V10P

Страница 1: ...V V7P V10P Manual 1 3 en ...

Страница 2: ...nce When reselling this product hand over this manual to the new owner If you supply d b products please draw the attention of your customers to this manual Enclose the relevant manuals with the systems If you require additional manuals for this purpose you can order them from d b d b audiotechnik GmbH Eugen Adolff Strasse 134 D 71522 Backnang Germany T 49 7191 9669 0 F 49 7191 95 00 00 docadmin d...

Страница 3: ...1 Product description 5 2 2 Connections 6 2 3 Operation 6 2 3 1 Controller settings 6 2 4 Dispersion characteristics 8 2 5 Technical specifications 11 3 Manufacturer s declarations 13 3 1 EU conformity of loudspeakers CE symbol 13 3 1 1 WEEE Declaration Disposal 13 Contents d b V7P V10P Manual 1 3 en 3 ...

Страница 4: ...ies as detailed in our specific Mounting instructions or in our Flying system and Rigging manuals Ensure that all additional hardware fixings and fasteners used for installation or mobile deployment are of an appropriate size and load safety factor Pay attention to the manufacturers instructions and to the relevant safety guidelines Regularly check the loudspeaker housings and accessories for visi...

Страница 5: ...tal grill backed by an acoustically transparent foam The cabinets are fitted with three types of rigging devices Two M10 threaded inserts on the top and bottom panels each to accept either the Z5383 VP Mounting bracket the Z5384 VP Flying adapter or the Z5388 VP Horizontal bracket Three additional combined sockets A one in the top panel and two at the rear of the cabinet that accept either the Q90...

Страница 6: ...without the need for an additional sense wire For applicable loudspeakers LoadMatch is therefore independent of the connector type used 2 3 Operation NOTICE Only operate d b loudspeakers with a correctly configured d b amplifier otherwise there is a risk of damaging the loudspeaker components Applicable d b amplifiers D80 D20 D12 30D Application Setup Cabinets per channel V7P V7P 2 V10P V10P 2 For...

Страница 7: ...om or auditorium CPL function The CPL Coupling function compensates for coupling effects between the cabinet and close boundary surfaces CPL begins gradually around 1 kHz with the maximum attenuation below 400 Hz To achieve a balanced frequency response the CPL function can be set to dB attenuation values between 0 and 9 Positive CPL values create an adjustable low frequency boost 0 to 5 dB at aro...

Страница 8: ...frequency of a single cabinet plotted using lines of equal sound pressure isobars at 6 dB and 12 dB Isobar diagram horizontal V7P vertical setup Isobar diagram vertical Isobar diagram horizontal V7P horizontal setup horn rotated Isobar diagram vertical d b V7P V10P Manual 1 3 en 8 ...

Страница 9: ...Isobar diagram horizontal V10P vertical setup Isobar diagram vertical Isobar diagram horizontal V10P horizontal setup horn rotated Isobar diagram vertical d b V7P V10P Manual 1 3 en 9 ...

Страница 10: ...e graphic opposite The HF horn can be rotated through 90 Tools required Torx wrench TX20 1 Undo the torx screws on the top and bottom panels of the cabinet and remove the front grill 2 Undo the screws holding the horn flange and rotate the horn 3 Refit the horn as follows Make sure the gasket of the horn is in place Refit the horn Insert all screws and carefully tighten them clockwise until they f...

Страница 11: ...nce 8 ohms Power handling capacity RMS peak 10 ms 500 2000 W Nominal dispersion angle horizontal V7P 75 Nominal dispersion angle horizontal V10P 110 Nominal dispersion angle vertical 40 Components 2 x 10 LF driver with neodymium magnet 1 x 8 MF driver with neodymium magnet 1 4 exit compression driver Passive crossover network Connections 2 x NLT4 F M optional 2 x NL4 M or 2 x EP5 Pin assignment NL...

Страница 12: ...V7P V10P cabinet dimensions in mm inch d b V7P V10P Manual 1 3 en 12 ...

Страница 13: ...ons of the respective EC directives including all applicable amendments A detailed declaration is available on request and can be ordered from d b or downloaded from the d b website at www dbaudio com 3 1 1 WEEE Declaration Disposal Electrical and electronic equipment must be disposed of separately from normal waste at the end of its operational lifetime Please dispose of this product according to...

Страница 14: ...D2722 EN 01 10 2016 d b audiotechnik GmbH www dbaudio com ...

Отзывы: