d&b Q-Series 31
The D6 and D12 amplifiers
power consumption and power loss
Signal waveform
CF
Duty
P
out
[W]
P
in
[W]
P
loss
[W] I
in
[A] U
in
[V]
1560 360 6.8 230
Sine wave
1.4
1/1
1200
1645
445
14.3
115
1715 515 17.2 100
Highly
520
120
2.3
230
compressed
2.4
1/3
400
550
150
4.8
115
music
1
570 170 5.7 100
Music with
215
65
1.0
230
low dynamic
4.0
1/8
150
220
70
2.0
115
range
220 70 2.2 100
Key:
CF:
Crest factor,
Duty:
Duty cycle,
P
out
[W]:
Max. average output power (sum of both channels),
P
in
[W]:
Input power (effective power)
P
loss
:
Power loss (thermal power),
I
in
[A]:
Resulting current,
U
in
[V]:
Mains voltage
D6 Power balance
Signal waveform
CF
Duty
P
out
[W]
P
in
[W]
P
loss
[W] I
in
[A] U
in
[V]
20.6
2
230
Sine wave
1.4
1/1
2400
3480
1080
41.2
2
115
47.4
2
100
Highly
9.2
230
compressed
2.4
1/3
800
1230
430
18.4
2
115
music
1
20.2
2
100
Music
with
5.3
230
low dynamic
4.0
1/8
400
640
240
10.6
115
range
11.2
100
D12 Power balance
Mains supply
Maximum number
D6
D12
230 V/16 A
4
2
115 /100 V/15 A
2
1
D6 and D12 power consumption and power loss
The power required from the mains supply and the waste heat
produced by the amplifier power loss vary depending on the load
impedance and the signal levels and characteristics (e.g. speech,
music). In practice, the theoretical peak power consumption of a
system will only be sustained for a short period of time. Basing
mains current and air conditioning plant requirements on the
peak power consumption of the sound system would result in a
generously overspecified installation. The key factor in power
consumption calculations is the crest factor of the music or speech
signal - the ratio of peak to sustainable RMS voltage of the
signal. The table below gives power figures for various types of
signal waveforms.
Mains supply
Maximum number of devices per phase conductor when full
output power is required:
In the USA and Japan we recommend the operation over two
phase conductors (phase to phase – 240 /200 V) or the use of
mains leads with a much higher cross section.
1
Maximum practicable operation
2
Only in conjunction with appropriate mains power supply installation
Содержание Q Series