INSTALLATION INSTRUCTIONS

PREPARING THE ENCLOSURE

Gloves and safety goggles should be worn during 

installation.

It is not recommended to install the appliance into a 

corner or directly beside a wall. The door will need 

to be opened more than 90° to allow full extension 

of the shelves. If it is necessary to place the unit next 

to a wall or in a corner, leave at least 5-10 cm of 

space between the wall and the appliance to allow 

for the door opening.

The cabinet opening must be at least 61.5 cm wide 

by 83 cm high by 59 cm deep.

Note: 

The listed depth requirement is assuming 

that the electrical outlet is located in the adjacent 

cabinetry or fl ush mounted in the rear wall, not 

surface mounted inside the enclosure.

If the electrical outlet is located inside adjacent 

cabinetry, cut a 3.8 cm diameter hole to admit the 

power cord. If the cabinet wall is metal, the hole 

edge must be covered with a bushing or grommet.

See image below.

REQUIRED TOOLS

• Safety 

goggles

• Gloves

• Tape 

measure

• Carpenter 

square

• Level

• Flashlight

•  Electric drill with hole bit

Tape measure 

Carpenter square

Electric drill with hole bit 

Gloves

Level

Safety goggles

Flashlight

Electrical Access

Electrical Access

*If electrical outlet in 

  adjacent cabinetry

83 cm

5 cm

15.2 cm

3.8 cm diameter

61.5 cm

90°

59 cm

Содержание DWC134KD1BSS

Страница 1: ...OWNER S MANUAL Distributed by Exertis UK Ltd Technology House Magnesium Way Hampton Burnley England BB12 7BF 2019 10 31 WINE COOLER Owner s Manual 1 9 MODEL MODÈLE MODELO DWC134KD1BSS ...

Страница 2: ...s R600a flammable and explosive articles should not be put in or near the cabinet to avoid fire or explosion Important Safety Information READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAFETY REQUIREMENTS To reduce the risk of fire electrical shock or injury when using the appliance follow these basic precautions DANGER Risk of fire or explosion Flammable refrigerant used Do not puncture refrigerant tubing D...

Страница 3: ...round prong from the power cord Do not use extension cords or ungrounded two prongs adapters If the power supply cord is damaged it must be replaced by the manufacturer its service agent or similar qualified person in order to avoid hazard LOCATION Remove interior and exterior packaging prior to installation Wipe the outside of the appliance with a soft dry cloth and the inside with a lukewarm wet ...

Страница 4: ...he listed depth requirement is assuming that the electrical outlet is located in the adjacent cabinetry or flush mounted in the rear wall not surface mounted inside the enclosure If the electrical outlet is located inside adjacent cabinetry cut a 3 8 cm diameter hole to admit the power cord If the cabinet wall is metal the hole edge must be covered with a bushing or grommet See image below REQUIRED...

Страница 5: ... clockwise until the appliance is level STOCKING INSTRUCTIONS This wine cooler has a maximum capacity of 46 750 ml Bordeaux wine bottles The upper chamber can hold a total of 16 bottles The lower chamber can hold a total of 30 bottles Note that bottles should be stored head to tail to reach maximum storage capacity as shown below The lower half shelves can be stocked as shown below UNDER COUNTER B...

Страница 6: ...ing in the upper chamber is 6 C The temperature in the upper compartment can be set as low as 5 C or as high as 10 C The default temperature setting in the lower compartment is 12 C The temperature in the lower chamber can be set as low as 10 C or as high as 18 C Actual temperature inside the appliance can vary based on ambient temperature how often the door is opened and how many warm bottles hav...

Страница 7: ...rn the lower hinge over and install it on the lower left side of the cabinet 5 When reinstalling the door it will need to be flipped 180 from its original position to ensure that the handle is on the correct side Install the actuator at the top of the door frame Screw holes can be found by gently pulling back the rubber gasket Install the axis plate and the door stop on the upper right side of the ...

Страница 8: ...ing Defrost water from the appliance is channeled into a drip tray located above the compressor Heat transfer from the compressor causes the defrost water to evaporate VACATION Short vacations Leave the appliance operating during vacations of less than three weeks Long vacations If the appliance will not be used for several months remove all items and turn off the appliance Clean and dry the inter...

Страница 9: ...t shut properly or opened excessively Ambient temperature or humidity is very high Excessive noise Appliance is not level Gurgling noises are normal this is the coolant moving through the lines in the cabinet Contraction and expansions of the inside walls can cause crackling or popping noises especially if the ambient temperature is very warm Door will not close Appliance is not level Door gasket ...

Страница 10: ...rsupplysuchaslowvoltage defectivehousewiringorinadequatefuses 4 Accident alteration abuseormisuseoftheappliancesuchasinadequateaircirculationintheroomorabnormaloperatingcon ditions extremelyhighorlowroomtemperature 5 Useforcommercialorindustrialpurposes ie Iftheapplianceisnotinstalledinadomesticresidence 6 Fire waterdamage theft war riot hostility actsofGodsuchashurricanes floodsetc 7 Servicecalls...

Страница 11: ...____________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ _______________________...

Страница 12: ...MODEL Printed in China Distributed by Exertis UK Ltd Technology House Magnesium Way Hampton Burnley England BB12 7BF DWC134KD1BSS ...

Отзывы: