Danby DKC445 Скачать руководство пользователя страница 9

7

CHILL'N TAP ASSEMBLY INSTRUCTIONS CON’T

1 6 . Installation of the Keg Coupler: IMPORTA N T

N O T I C E ; Make sure the black pull handle of the 
keg coupler is in the "upward" (closed) position 
before installing on the beer keg. See Fig. 9 Insert 
the keg coupler into the locking neck of the beer 
keg and apply a 1/4 turn clockwise to lock into 
p o s i t i o n .

1 7 . Installation of the CO2 Air Line Hose to the Keg

C o u p l e r : Attach the open end of the (red) air line 
hose to the hose barb connection on the keg 
c o u p l e r. Secure hose by using the remaining (self 
locking) plastic snap on clamp provided. (use pliers
to tighten clamp and assure there are no leaks)

1 8 . Installation of the Beer Line Hose to the Keg 

Coupler: IMPORTANT NOTICE: The black rubber
washer (provided) must be installed inside the 
wing nut before connecting the beer line to the keg
c o u p l e r. Remove the black rubber protective cap 
located on top of the keg coupler and screw the 
wing nut (with rubber washer) onto the keg 
c o u p l e r. (hand tighten firmly)

1 9 . Making the connection between the Keg 

Coupler and Beer Keg: Before making (opening) 
connection between the keg coupler and beer keg,
make sure the beer tower faucet is in the closed 
position. (faucet handle straight back) To engage 
the tank connection, pull the keg coupler handle 
out and push down until it locks into position. 
Listen for positive "click" of the pull handle in the 
final downward position. See Fig. 10 

2 0 . Opening the CO2 Cylinder Main Va l v e : Before 

opening the main valve located on top of the CO2 
c y l i n d e r. Make sure the "secondary" shut-off valve 
located on the lower stem pipe of the regulator is 
in the "closed" position. See Fig. 11
N O T E : 
When the secondary valve (handle) is 
positioned "Horizontal" (east/west) the valve is 
c l o s e d .

When the secondary valve (handle) is positioned 
" Vertical" (north/south) the valve is open.
To open the main CO2 cylinder valve, (slowly) turn 
the main valve counter clockwise until fully open. 
You will notice the needles on both gauges start to 
climb.        

2 1 . Adjusting the CO2 Regulator: There are two 

pressure gauges on the CO2 regulator. 
See Fig. 12 The upper gauge #1 monitors "LOW" 
(internal keg) pressure  and must be adjusted to 
the correct operating pressure of 10~12psi/lbs. T h e
lower gauge #2 monitors "HIGH" (CO2 cylinder) 
pressure and is not adjustable. The high pressure 
gauge also acts as a fuel gauge to let you know 
when the C02 cylinder needs re-filling.

I M P O R TA N T: The internal operating pressure of the
beer keg should be adjusted  and maintained between
10 ~ 12psi/lbs. To adjust the "low" pressure gauge;
• Using an adjustable wrench, release the adjustment 

lock nut # 3. See Fig. 12

• Using a flat screwdriver, turn the regulator 

adjustment screw # 4 See Fig. 12
Clockwise rotation of the adjustment screw will 
increase low pressure.
Counter clockwise rotation of the adjustment screw 
will decrease low pressure

• When the required operating pressure is attained 

retighten the adjustment lock nut # 3.

• You are now ready to serve cold beer

Fig. 9

Fig. 10

Fig. 11

Fig. 12

2

1

4

5

6

3

Secondary
Shut-off
Valve

Содержание DKC445

Страница 1: ...que d identification située sur le panneau arrière de l appareil Il est possible d acheter les pièces de rechange ou de les obtenir par commande spéciale en vous rendant à votre service après vente le plus proche Pour effectuer des réparations ou obtenir l adresse du service après vente le plus proche veuillez composer le NUMÉRO SANS FRAIS Pour effectuer des réparations ou commander des pièces de ...

Страница 2: ...de sécurité et les instructions d utilisation avant l utilisation initiale de ce produit PRECAUCIÓN Lea y observe todas las reglas de seguridad y las instrucciones de operación antes de usar este producto por primera vez Danby Products Limited Guelph Ontario Canada N1H 6Z9 Danby Products Inc Findlay Ohio USA 45840 DKC445BL 11 00 Keg Cooler Owners Manual Glacière de bière en fût Guide d utilisation...

Страница 3: ...gerator application This refrigerator is for domestic use only and is intended for storing fresh foods at temperatures higher than 32ºF 0ºC Model Number ___________________________ Serial Number ______________________________ Date of Purchase ________________________________________________________________________ Dealer s Name and Address __________________________________________________________...

Страница 4: ...ket and or adjust the door IMPORTANT This appliance must be connected to a properly grounded electrical outlet see Grounding Instructions If food or beverage has a strange smell or color throw it away because it is likely that it has spoiled and therefore dangerous to consume Always disconnect the appliance from the power supply before cleaning and or attempting repairs servicing WARNING Repairs s...

Страница 5: ...rom heat emitting sources This appliance is designed for indoor use only and should not be used outdoors This appliance is inclusive of an in wall static type condenser and should not be built in recessed unless adequate ventilation is provided to maintain proper cooling minimum 2 3 inches clearance required on all sides If the unit as a Keg Cooler application is to be built in remember this will ...

Страница 6: ...Always connect CO2 gas cylinder to a regulator Failure to do so could result in an explosion with possible death or injury when the cylinder valve is opened 2 Never connect C02 gas cylinder directly to beer keg 3 Always secure C02 gas cylinder in an upright position 4 Always keep CO2 gas cylinder away from heat 5 Never drop or throw CO2 gas cylinder 6 Always check the D O T Department of Transport...

Страница 7: ... the smaller screws at the front the larger screws at the rear 4 Installation of CO2 Cylinder Support Install the cylinder support onto the four studs located on the exterior back wall of the cabinet no tools required Align the holes in the cylinder support with the studs and push down firmly See Fig 3 5 Installation of CO2 Cylinder Install your fully charged CO2 cylinder into the support stand IM...

Страница 8: ...e of the beer tower gasket and bayonet The beer faucet should be aligned with the F on the bayonet and facing the front of the cabinet 6 00 o clock position Using a Phillips Screwdriver attach the beer tower to the bayonet using four machine screws provided and tighten firmly To remove unlock the beer tower assembly from the cabinet grasp the tower and 1 4 turn counter clock wise until it stops an...

Страница 9: ...0 20 Opening the CO2 Cylinder Main Valve Before opening the main valve located on top of the CO2 cylinder Make sure the secondary shut off valve located on the lower stem pipe of the regulator is in the closed position See Fig 11 NOTE When the secondary valve handle is positioned Horizontal east west the valve is closed When the secondary valve handle is positioned Vertical north south the valve i...

Страница 10: ...ator compartment is controlled by adjusting setting the thermostat con trol knob located on the ceiling of the refrigerator cabinet To start the refrigerator and achieve maximum cooling quickly Turn the temperature control knob using a coin or screwdriver clockwise to the furthest maximum setting on the darker blue section of the graduated control dial See Fig 14 Allow the refrigerator to run at t...

Страница 11: ...rost the refrigerator because ice depositing on the evaporator is defrosted automat ically Ice build up on the evaporator during compressor operation will when the compressor has cycled off defrost automatically Defrost water collects inside the drain trough and passes through the drain outlet in the rear wall into a drain pan situated above the compressor where it evaporates CLEANING THE APPLIANC...

Страница 12: ...xcessive agitation occurs during transportation allow keg to settle for 1 2 hours before tapping Prior to tapping the keg ensure the beer faucet is in the off position Completely remove the dust cover identification cap from the beer keg Check that the keg coupler handle is in the up off position See Fig 9 Insert the keg coupler into the locking neck of the beer keg and apply a turn clockwise to l...

Страница 13: ...ross the warmer ambient surfaces of the inner faucet Always make sure the faucet handle is pushed fully back closed to prevent excess dripping A beer faucet lock kit for the purpose of limiting access is readily available and can be purchased through our after sales service department at 1 800 26 DANBY 1 800 263 2629 Why do dispensing lines have to be cleaned Beer lines have to be cleaned because ...

Страница 14: ... the top of the cabinet 10 Install the Chill N Tap cabinet plug worktop 11 Install the 2 cantilever wire shelves onto the factory installed cantilever support brackets located on the rear wall of the refrigerator cabinet 12 Adjust the refrigerator temperature as required The conversion process is now complete Please make sure all Chill N Tap accessories removed are stored in a safe place for futur...

Страница 15: ...that Danby will be responsible or liable for any spoilage or damage to food or other contents of this appliance whether due to any defect of the appliance or its use whether proper or improper EXCLUSIONS Save as herein provided Danby Products Limited Canada or Danby Products Inc U S A there are no other warranties conditions representations or guar antees express or implied made or intended by Dan...

Отзывы: