READ ALL SAFETY INFORMATION BEFORE USING

1)

All wiring must comply with local and national electrical

codes and must be installed by a qualified electrician. If you

have any questions regarding the following instructions, 

contact a qualified electrician. 

2)

Check available power supply and resolve any wiring 

problems BEFORE installing and operating this unit.

3)

This 115V air conditioner uses 10 or less nameplate amps

and may be used in any properly wired, general purpose

household receptacle. See Table 1 for specifications for 

individual branch circuit.

4)

For your safety and protection, this unit is grounded

through the power cord plug when plugged into a matching

wall outlet. If you are not sure whether your wall outlet is

properly grounded, please consult a qualified electrician. 

5)

The wall outlet must match the 3-prong plug on the service

cord supplied with the unit. DO NOT use plug adapters. See

Table 2 for receptacle and fuse information. If it is necessary

to use an extension cord to connect your air conditioner, 

use

an approved “air conditioner” extension cord only 

(available at most local hardware stores). 

6)

The rating plate on the unit contains electrical and other

technical data. The rating plate is located on the right side of

the unit, above the power cord. 

TABLE 1

Suggested Individual Branch Circuit

Nameplate Amps

*AWG Wire Size

4.9 to 10

14

AWG- American Wire Gauge

*Based on copper wire at 60°C temperature rating.

TABLE 2

Receptacle and Fuse Types

Rated Volts

125

Amps

15

Wall Outlet

Fuse Size

15

Time Delay Fuse

Plug Type

(or Circuit Breaker)

ELECTRICAL

SPECIFICATIONS

Fresh Air Ventilation Switch

(open for Fan only operation

Cabinet

Exterior air

inlet

Filter

Interior air 

outlet

Interior air

inlet

Control

Panel

PART IDENTIFICATION

IMPORTANT SAFETY INFORMATION

2

CAUTION:

Do not leave this unit 

unattended in a space where people or 

animals cannot react to a failed unit are 

located. A failed unit can cause extreme 

overheating or death in such an enclosed,

unattended space. 

Содержание dac12077ee

Страница 1: ...te du climatiseur ce manuel doit tre inclus avec l appareil CAUTION Read and follow all safety rules and operating instructions before first use of this product MISE EN GARDE Veuillez lire attentiveme...

Страница 2: ...ate of Purchase This information will be necessary if your unit requires servicing and or for general inquiries To contact a Customer Service Representative call Danby TOLL FREE 1 800 26 1 800 263 262...

Страница 3: ...ers See Table 2 for receptacle and fuse information If it is necessary to use an extension cord to connect your air conditioner use an approved air conditioner extension cord only available at most lo...

Страница 4: ...crews 9 Factory installed on some models Safety Lock 1 Adhesive Foam Seal 1 Sash bracket 2 L Shaped mounting bracket 1 INSTALLATION HARDWARE Your Room Air Conditioner is designed for easy installtion...

Страница 5: ...electrical outlet is within reach of the installation Use only a single outlet circuit rated at 15 amps All wiring should be in accordance with local and national electrical codes F DO NOT install uni...

Страница 6: ...side and secure the top of the frames to the window sash using one 3 4 screw on each side and one in the L shaped mounting bracket Fig 5 Secure the shutter clamp on each side of the lower shutter and...

Страница 7: ...the program is complete the air conditioner will resume to its previous set temperature before sleep mode was activated This feature is meant to be used during the night time hours to prevent the roo...

Страница 8: ...cklight on off 12 Restore remote control default settings To operate the hand held remote control will require two AAA Alkaline batteries included Batteries should be replaced when a No signal beep is...

Страница 9: ...thoroughly before re installing CLEANING AIR FILTER 1 Use a vacuum cleaner with soft brush attachment 2 Wash the filter in lukewarm water below 40 C 104 F To get best results wash with soapy water or...

Страница 10: ...or outdoor louvres Turn the unit off and wait 5 minutes before attempting to restart Tighten loose parts Provide additional support to unit Clean unit thoroughly Place algaecide tablet in base pan Con...

Страница 11: ...le Num ro de s rie Date d achat Ces renseignements seront requis si le service est demand et ou si vous d sirez obtenir des renseignements suppl mentaires Pour consulter un Repr sentant du service la...

Страница 12: ...en qualifi 5 La prise murale doit correspondre la fiche 3 broches sur le cordon de service fourni avec l appareil N utilisez PAS de fiches d adaptation Voir Tableau 2 pour les renseignements sur les p...

Страница 13: ...lus difficile manipuler Un soutien inappropri du c t des commandes de l appareil peut causer des blessures et endommager l appareil et d autres biens mobiliers C est pourquoi il est recommand que quel...

Страница 14: ...bloquer le flux d air E Assurez vous que la prise lectrique appropri e se trouve la port e de l installation N utilisez qu un circuit prise unique calcul 15 amp res Tout le c blage doit tre conforme a...

Страница 15: ...volets compl tement de chaque c t et fixez le haut des structures au cadre de la fen tre en utilisant une vis de 3 4 po et une rondelle de s curit sur chaque c t Fig 5 Coupez la bande mousse adh sif a...

Страница 16: ...un 1 heures la nouvelle temp rature est maintenue pendant sept 7 heures Une fois que le programme est complet le climatiseur reprendra la temp rature de climatisation votre pr r glage avant que le mod...

Страница 17: ...es arrangements de t l commande au r glages par d faut Deux piles alcalines AAA sont requises pour le fonctionnement de la t l commande incluses Les piles devraient tre remplac es quand a Aucun signal...

Страница 18: ...un aspirateur de poussi re muni d une brosse douce 2 Lavez le filtre dans de l eau ti de de moins de 40 C 104 F Pour obtenir de meilleurs r sultants lavez avec une eau savonneuse ou un agent neutre d...

Страница 19: ...strue la grille ou les volets ext rieurs Arr tez le climatiseur et attendez 5 minutes avant de le remettre en marche Serrez les pi ces qui sont desserr es ou ont de jeu Fournissez un support suppl men...

Страница 20: ...esting service or ordering parts always provide the following information Product Type Model Number Part Number Part Description Le num ro de mod le se trouve sur la plaque d information sur le pannea...

Отзывы: