Controller Integration
When the Danalock has been included into the network, the controller should:
•
Set the Lifeline. Association group 1
•
Enable Notification for Access Control
Test information
Configuration Parameters
When testing config parameter 4. Be aware that this is a count down, so a set and then a get will not return the
same value.
Battery Warning
To get the lock to send a battery warning the voltage must be low AND the motor must be operated. The lock
only measures the battery voltage under load to get the most precise result. By using a 1 A voltage adjustable
transformer with approximately 1 meter of wire the following data has been collected.
Voltage
Battery report value
12 V
0x62 (98%)
9V
0x26 (38%)
7,5V
0x0B (11%) (Battery warning is send)
No reports received
If no reports are received from the lock it is most likely because the lock is not calibrated and thereby does not
no know when the lock is lock or unlock and therefore it does not send reports to the gateway. There are two
ways to calibrate the lock.
1.
Autocalibration. Turn the Danalock manually until the door is unlocked and leave the door open while
calibrating. Lift the handle if needed. Now click 3 times, after 5 seconds the Danalock will calibrate.
2.
Manual calibration (start by turn to unlock). Turn the Danalock completely into unlock position, then
click twice. Wait 5 seconds until it flashes yellow, then turn the Danalock into locked position and click
once.