Configuration CC V1 (secure)
Z-Wave
parameter
no.
Parameter Name
Parameter
Size
Default
value
Description
1
TWIST_ASSIST
1 Byte
0
0 = Disabled, 1=Enabled
2
HOLD_AND_RELEASE (brake and go back) 4 Bytes
0
0=Disabled, 1-2147483647
(hold seconds)
3
BLOCKED_2_BLOCKED(async)
1 Byte
0
0 = Disabled, 1=Enabled
4
BLE_TEMPORARY_ALLOW_TIMER
4 bytes
0
0=Disabled, 1-2147483647
(seconds to allow)
5
BLE_ALWAYS_ALLOWED
1 byte
0
0 = Disabled, 1=Enabled
6
Autolock
4 bytes
0
0 = Disabled, 1-2147483647
seconds of delay before
autolock enable.
Device Reset Locally CC V1 (unsecure)
When the Z-Wave module is reset it sends a report to tell the controller it has been reset. The lock is reset by
pushing the switch 10 times. Please use this procedure only when the primary controller is missing or otherwise
inoperable
Door Lock CC V2 (secure)
Door Lock Operation is used to lock and unlock the Danalock. See table to see how the Door Lock Mode
paramater affects the lock.
Door Lock Operation
Paramater
Secured Unsecured
Door Lock Mode 0xFF
0x00-0xEF
In a Door Lock Operation Report the Danalock will report:
Door Lock Operation Report
Value\Door status
Unlocked Locked
Door Lock Mode
0x00
0xFF
Handles
0x11
0x11
Door Condition
0x02
0x05
Lock Timeout Minutes 0xFE
0xFE
Lock Timeout Seconds 0xFE
0xFE
The Danalock does not use the Door Lock Configuration to adjust settings, the Configuration CC is used
instead. The Danalock ignores Door Lock Configuration Set frames and response a Door Lock Configuration
Get with:
Door Lock Configuration Report
Parameter
Value
Operation Type
Constant operation(0x01)
Handles
Handle 1 enabled (0x11)
Lock Timeout Minutes Timeout not supported(0xFE)
Lock Timeout Seconds Timeout not supported(0xFE)