9
F7 Output 2 Time:
Sets the amount of time Output 2 will be active after the Preset is reached. Choices
are the same as Output 1
E
F7
PRG
0
F9 Output on Reset:
When set to ON (1), the primary output (Output 2 on dual preset version) will
activate when the unit is reset.
E
F9
PRG
. 1 0
F10
PRG
F10 Input Type:
Enables the unit to be programmed to work with either sinking or sourcing inputs.
Choices are NPN (0), and PNP (1)
F11 Count Speed:
Enables the unit to be set for full speed of 5 kHz (1) or to 30 Hz (0) to provide debounce
filtering for contact inputs.
F12
PRG
0
F12 Static/Dynamic Reset:
When set to static reset (0) counting stops on the leading edge of the reset
input and does not resume until the trailing edge. When set to dynamic reset (1) the Count Value is
immediately reset on the leading edge of the reset signal, and will accumulate while the reset signal is still
active.
F14
PRG
0
F14 Output Signal Memory:
Determines if after power interruption the outputs will resume their state
prior to the loss of power (1) or if the output will be reset (0)
E
E
E
E
PRG
1
F11
1
F20
PRG
F20 Front Panel Reset Enable:
When active (0), the count value and output(s) can be reset by
simultaneously pressing the "6" and "4" keys. If set to Off (1), reset can only take place through the
remote input, or through the front panel by holding the "6" and "4" keys for 10 seconds (see F29).
0
E
F15 Background Totalizer:
Setting this parameter to ON (1) will activate the totalizer function.
PRG
0
F15
E