13
ELAPSED TIME MODE
If the functionality has been set to FN2, then the unit will operate as an
elapsed time counter, in one of 3 programmable operation modes. To
enter the Program mode, hold down the Edit key and the "5" key during
power-up. Use the edit key to move from one parameter to the next,
and the "1" key to scroll through the parameter choices. Holding down
the Edit key for 5 seconds will return the unit to Operation mode.
5
E
F0
PRG
0
F0 Default Settings:
Changing this value from 0 to 1 will set all parameters back to their default values. A
setting of 0 has no effect on the other parameters.
During Power-up
E
F2
PRG
0
F2 Time Format:
Sets the units in which will be used for the timing display. Choices are seconds (0),
minutes (1) and hours (2).
F4 Reset Operation:
Defines how the time value will behave when the preset is reached. Choices are:
F6 Output 1 Time:
Sets the amount of time Output 1 will be active once the Preset is reached. Choices
are:
F7 Output 2 Time:
Sets the amount of time Output 2 will be active once Preset 1 is reached. Choices are
the same as for Output 1.
F8 Timing Operation:
The unit can be programmed to operate in one of 4 modes:
F3
PRG
0
E
F4
PRG
0
Code
0
Reset to "0", no Autoreset
1
Reset to "0", Autoreset
2
Reset to Preset, no Autoreset
3
Reset to Preset, Autoreset
F6
PRG
.10
Code
Off
No output
On
Latching output (for dual presets, output 2 will deactivate output 1 )
0.02
20 ms
0.05
50 ms
0.10
100 ms
0.50
500 ms
1.00
1 sec.
E
F7
PRG
.10
E
E
F8
PRG
Code
0
Cumulative pulse width measurement
1
Cumulative period measurement
2
Singular Pulse width measurement
3
Singular Period measurement
E
Note: Timing diagrams for each mode are included at the end of this section
F3 Display Decimal Point:
Defines the number of digits displayed to the right of the decimal point for the
Time and Preset values. Settable in a range from 0 to 3.
0