9.7
Warning messages
Faults which occur, but which do not cause a switch-off of the amplifier output stage
(BTB/RTO contact remains closed), are indicated in the LED display on the front panel by
a coded warning number.
Number
Designation
Explanation
E / P
Status Messages
Status messages, no error, see p. 96
. . .
Status Message
Amplifier is updating the startup configuration
- S -
AS-Enable
AS-Enable input is 0V (with disabled drive only)
-
Status Message
Status message, no error, programming mode
n01
I²t
I²t threshold exceeded
n02
Regen power
Reached preset regen power limit
n03*
S_fault
Exceeded preset following error limit
n04*
Response monitoring
Response monitoring (fieldbus) has been activated
n05
Supply phase
Mains supply phase missing
n06*
SW limit switch 1
Software limit switch 1 underrun
n07*
SW limit switch 2
Software limit switch 2 overrun
n08
Motion task error
A faulty motion task was started
n09
No reference point
No reference point (Home) set at start of motion
task
n10*
PSTOP
PSTOP limit-switch activated
n11*
NSTOP
NSTOP limit-switch activated
n12
Motor default values
loaded
Only for ENDAT or HIPERFACE
®
:
discrepancy between motor number saved in the
encoder and the amplifier, motor default values loa-
ded
n13*
Expansion card
24V DC supply for I/O expansion card not ok
n14
SinCos feedback
SinCos commutation (wake & shake) not comple-
ted, will be canceled when amplifier is enabled and
wake & shake carried out
n15
Reserve
Reserve
n16
Summarized warning
Summarized warning for n17 to n31
n17
Fieldbus-sync
CAN sync is not logged in
n18
Multiturn overflow
Max. number of motor turns exceeded
n19
Motion task ramps are
limited
Range overflow on motion task data
n20
Invalid motion task
Invalid motion task
n21
PLC program error
For details see PLC code
n22
Max. motortemperatur
reached
The user can shut down the process before the tem-
perature eror will interrupt the process immediately
n23
Sin Cos feedback
Warning level reached
n24
Digital I/O
Configuration is not logical
n25-n31
Reserve
Reserve
n32
Firmware beta version
Firmware is an unreleased beta version
* = these warning messages result in a controlled shut-down of the drive (braking by
emergency stop ramp)
More information to the messages can be found in the ASCII Object Reference
(Online Help), see parameter STATCODE. Hints for removal can be found in the
Online help chapter "Trouble-Shooting".
SERVOSTAR
®
300 Product Manual
99