background image

D

INSTALLATION

6. Mount unit cabinet to the wall. Insert power cord 

through the inlet hole located in the back of the cabinet, or 

through the premade opening at the bottom of the cabinet. 

Connect power cord to hand dryer. It may be necessary to 

remove a plate to push the cord through.

POWER CORD

8. Remove end cap from blind plug. Pull wires and earthing 

through the flexi hose and air branch on motor. Fasten the 

flexi hose to the cabinet branch. Attach the opposite end of 

the flexi hose to branch on tap.

BLIND PLUG

INSTALLATION

Make sure the main breaker is turned off. Installation must be carried out by a 

 

qualified person in accordance with applicable standards in the country concerned.

3. Mark the desired postion on the wall and drill a Ø35 

mm diameter hole.

4. Installation of the tap:

 

  A) Push the screwed bushing through the hole 

 

  in the wall

 

  B) Place gasket, disc, and nut on the threaded 

 

  coupling of the tap

 

  C) Tighten with tool, be careful not to overtighten 

 

  the nut.

Recommended wall 

thickness: 10-30 mm 

Gasket

Disc

Nut

5. Unscrew (2) bottom screws and remove cabinet using   

     the allen wrench included .

1. Check the required distance from

 

  sensor to sink. 

30°

Ceramic ≥250 mm

 

Brushed steel ≥300 mm

Sensor

Sensor field of view:

 

Object distance 250 mm: D: ≤128 mm

 

Object distance 300 mm: D: ≤155 mm

Objects within range D may cause unintentional activation.

160 

D

2. Check the required distance from

 

  sensor to sink. 

Recommended wall thickness: 10-30 mm

 19 mm

≥170mm

30°

Sensor

A minimum distance 

of 180 mm is 

required between 

each tap product. 

≥180 mm

Distance 

from  

sensor to 

sink:

7. Connect supply wires to terminal block:

 

  A) Connect phase wire (black or brown) to terminal    

  block ”L”.

 

  B) Connect neutral wire (light blue) to terminal 

 

  block ”N”.

 

  C) Connect earthing (yellow/green) to terminal

 

  block ”     ” 

6

7

Содержание 372-373

Страница 1: ...USER MANUAL AIRTAP BUILD IN HAND DRYER Model 372 373 ...

Страница 2: ...L 372 373 Stainless steel satin finish AirTap Wall 230V 110V IMPORTANT This product falls within the scope of the WEEE directive on recycling and recovery of waste electrical and electronic equipment This product should not be disposed of with general household waste This product must be reused if possible Contact your local authority for further details This product may also be returned to the ma...

Страница 3: ... recommended by the manufacturer The product should be checked on a regular basis Never use a defective or malfunctioning unit Never make alterations to the product affecting its performance DAN DRYER s product warranty does not cover product problems that result from misuse or alteration NOTE Type Y connection If the power supply cord is damaged it must be replaced immediately Only qualified pers...

Страница 4: ...the tap A Push the screwed bushing through the hole in the wall B Place gasket disc and nut on the threaded coupling of the tap C Tighten with tool be careful not to overtighten the nut Recommended wall thickness 10 30 mm Gasket Disc Nut 5 Unscrew 2 bottom screws and remove cabinet using the allen wrench included 1 Check the required distance from sensor to sink 30 Ceramic 250 mm Brushed steel 300...

Страница 5: ...mer via respective ports 11 Connect earthing 12 Mount cabinet front and tighten 2 screws Ensure easy access to maintenance and cleaning of the unit Add extra space 30 mm at the air inlet if a HEPA filter should be fitted It is recommended to install a power switch to the hand dryer to ensure easy disconnection of electricity supply before cleaning and maintenance Do not turn or bend the flexi hose...

Страница 6: ...rtighten screws INSTALLATION HEIGHT RECOMMENDATION Tolerance for position of flexi hose from centre line 2 cm If tolerance for any reason deviates more than 2 cm on the determined installation position it must be ensured that the hose is not bent or curved A bent or curved hose can cause reduced air velocity and air volume CLEANING AND MAINTENANCE Routine cleaning and maintenance is recommended ev...

Страница 7: ...ows only cold air during a full cycle Disconnect the power Remove cabinet and disassemble the blower fan unit Test the thermostat for open circuit Check the heating element for defects Replace defect heating element LED indicator does not work Confirm the unit works properly If yes replace LED circuit board Hand dryer does not run smoothly Check carbon brushes Replace if they are worn or damaged I...

Страница 8: ... Cabinet front part 10 Threaded bushing 30 Hexagonal security screw 11 Small rubber gasket 31 Filter set filter and holder 12 Large rubber gasket 32 Rubber bush 13 Stainless steel disc 33 Earthing 14 Nut 34 Sensor cable 15 Flexi hose 30 cm 35 Nylon bushing 16 Clamp for flexi hose 2 pcs 36 Back plate 17 Stainless steel cabinet back 37 Earthing screw 18 Mounting cap 38 Insulation mylar 19 Gasket for...

Страница 9: ...DAN DRYER A S Alsikevej 8 DK 8920 Randers NV Tel 45 8641 5711 Email info dandryer com dandryer com ...

Отзывы: