STEP 8. WATERING TUBE INSTALLATION

Run the Watering Tube to the top of the piano as shown in

Figure 8, page 5. It’s important to curve the tube so it can be

pulled out freely for watering. Figure 19 

shows the two types

of watering tube clamps included with the System, the 1/2-inch

clamp and the half-clamp. At the top of the piano, mount half-

clamps to hold the end of the tube so it can be removed easily.

Use 1/2-inch screws with serrated washers to anchor the half-

clamps and washers (the serrated washers bite into the wood to

stabilize the clamp). Use the 1/2-inch clamps with 1/2-inch

screws to hold the watering tube between the half clamps and

the Humidifier.

MAKE A NEAT INSTALLATION:
Bundle and secure excess cords in the front and back of the

piano by using the remaining clamps mounted with 1/2-inch

screws.

STEP 9.  BACKSIDE COVER INSTALLATION

Install the Cover according to the instructions found in the Cover

box.

After the Piano Life Saver System and the Cover are com-

pletely installed,

 plug the Humidistat into a non-switchable wall

outlet where it cannot be turned off and therefore will be fully

energized at all times.

STEP 10. WATERING THE SYSTEM

The final step is to fill the Humidifier with water. FILL THE

WATERING CAN TO THE RED LINE ON THE LABEL. Instruct

the piano owner to add one can of water each time the yellow

Low Water Light blinks.

 Also instruct the piano owner to add

one capful of PAD Treatment to each full watering can. PAD

Treatment inhibits mildew in both the watering tube and the

Humidifier and increases the life of Humidifier pads.

Warning: Add only Dampp-Chaser PAD Treatment to the

Humidifier water. Other brands of water treatment may

contain acids which corrode strings and metal parts in the

piano. The use of other water treatment preparations will void

the warranty of the Piano Life Saver System and may void the

warranty of the piano manufacturer.

If tap water comes from a well or is “hard” water, meaning

containing significant minerals, we recommend using distilled

water. If distilled water is used, add PAD Treatment (according

to the label instructions) to ensure there are adequate electro-

lytes in the Humidifier to support operation of the low water

warning light. Without sufficient electrolytes, the light will blink

continuously, even when the Humidifier is full. 

Do not put salt

in the Humidifier, as it is corrosive.

To fill the Humidifier, simply pull the watering tube out of the half

clamps, connect the spout inside the watering tube, raise the

watering can, and add water. Then, disconnect the watering can

from the tube and push the tube back into the half clamps. The

System is designed so siphoning will not occur.
This completes the installation of the System.

Humidifier Maintenance:

 To ensure a properly functioning

Humidifier, the pads should be 

changed at least twice each

year

. This applies whether a Smart Bracket is used or not.

Change them during the fall service of the piano and then again

in the spring. Replacement pads can be obtained from Dampp-

Chaser or from any Dampp-Chaser distributor. Clean the

Humidifiers once yearly. When you clean the Humidifiers, also

replace the plastic Clean Sleeves on the Humidifier Heater Bars

to protect the Bars from excessive corrosive minerals in the

water. Cut the sleeves to the correct length.

Smart Bracket Maintenance:

 The sensor wires of the Smart

Bracket operate more effectively if the wires are kept free from

corrosion and minerals. During pad changing, remove the

Bracket from the Heater Bar. Remove the mineral residue on the

wires by scraping with the dull edge of a knife held perpendicu-

lar to the wire. Alternatively, it may be simpler to bring a new SB

to replace the old one.
You will need to cut the new SB to the correct length with a wire

cutter. Replacement SBs are available from your Dampp-

Chaser distributor.
DAMPP-CHASER’S TECHNICAL SERVICE DEPARTMENT

IS AVAILABLE TO ANSWER ALL INSTALLATION QUESTIONS

AT 800-438-1524.

A

B

FIGURE 19

Two types of clamps for Watering Tube

(A) 1/2-inch clamp

(B) half clamp

Содержание Piano Life Saver System

Страница 1: ...to check that none are missing prior to arriving at the installation location In the unlikely event that a part is missing please call 800 438 1524 with information from the end of the box and the assembler s name We will provide same day shipment of the replacement part NOTE Please read these instructions completely before beginning as some of the later steps are affected by earlier steps This Ba...

Страница 2: ...e of another brand of treatment voids the System s warranty and may also void the piano manufacturer s warranty OTHER IMPORTANT INFORMATION 1 The newly installed Piano Life Saver System will alter the piano s wood moisture content and therefore alter the tuning Ideally the System should be installed 3 weeks BEFORE the piano is tuned 2 A frayed or cracked electrical cord wire can cause a fire or sh...

Страница 3: ... push the pads down into the Humidifiers as shown in Figure 1 Note the plastic Clean Sleeves on the Humidifier Heater Bars The sleeve protects the Heater Bar from corrosion caused by excessive minerals in the water STEP 2 HUMIDISTAT INSTALLATION It should be noted that the two end vent holes on the top of the Humidistat above the Humidifier outlet act as a chimney to vent heat from the Humidistat ...

Страница 4: ... the wall Insert the 2 inch screws through the Humidistat case and into the wall Use the screws to mount the Humidistat Do not use the Velcro for permanent mounting FIGURE 5 Drill a hole in the corner of the bottom board FIGURE 4 FIGURE 7 Drill a 1 2 inch hole Figure 5 through the bottom board at the treble end that will enable you to run the Humidifier and Dehumidifier cords from the back of the ...

Страница 5: ...lip the tube end over the elbow on each Humidifier It s important that you support the elbow when pushing on it to avoid breaking the seal between the elbow and the Humidifer It may be easier to support the elbows with the Humidifiers outside the piano A little water on the inside of the tube ends will provide some lubricant to enable the tube to slip over the elbow Slip the locking rings onto the...

Страница 6: ...tribution Baffles above the Humidifiers between and at the top of the bays as shown in Figure 8 page 5 Properly installed the Baffle should resemble a small roof The Baffle is attached to the piano with two pin pegs pushed through the top of the Baffle roof one at each end into the wood of the piano Figure 13 Use Velcro to mount the Baffle where you encounter a metal surface STEP 5 DEHUMIDIFIER IN...

Страница 7: ...e is no damage remove the fuse from the brass clips inside the plug and replace it with the spare fuse in the plug If the cord is damaged the Humidistat should not be plugged into an electrical outlet Call our technical support number for instructions 800 438 1524 or 828 692 8271 Only 5 AMP 125 Volt 5 mm x 20 mm fast acting glass fuses should be used in the plug Never use a fuse with greater amper...

Страница 8: ...he warranty of the Piano Life Saver System and may void the warranty of the piano manufacturer If tap water comes from a well or is hard water meaning containing significant minerals we recommend using distilled water If distilled water is used add PAD Treatment according to the label instructions to ensure there are adequate electro lytes in the Humidifier to support operation of the low water wa...

Отзывы: